Experimental gallop rhythm in sheep with Gousiekte : correlation of changes in amplitude with haemodynamic parameters

Show simple item record

dc.contributor.author Van Rooyen, J.M.
dc.contributor.author Van Ryssen, J.C.J.
dc.contributor.author Minnaar, J.P.
dc.contributor.author Pretorius, P.J.
dc.contributor.editor Bigalke, R.D.
dc.date.accessioned 2014-10-16T06:03:50Z
dc.date.available 2014-10-16T06:03:50Z
dc.date.created 2014
dc.date.issued 1988
dc.description The articles have been scanned in colour with a HP Scanjet 5590; 600dpi. Adobe Acrobat XI Pro was used to OCR the text and also for the merging and conversion to the final presentation PDF-format. en
dc.description.abstract To investigate the correlation of haemodynamic parameters with the intensity of the gallop sound (S₃), use was made of right heart catheterization with a Swan-Ganz catheter to measure the pulmonary and right atrial pressures. The cardiac output was determined with the thermodilution method. A radiocardiogram was obtained after a bolus injection of technetium pertechnetate. The cardiopulmonary flow-index was obtained from the simultaneous recordings of the radiocardiogram and an electrocardiogram. With the haemodynamic parameters, heart sounds were recorded simultaneously and externally with a microphone. Eight Merino sheep were dosed with dried Pachystigma pygmaeum (Schltr) Robyns plant material through rumen fistulas until the clinical symptoms of heart failure such as gallop sounds, systolic murmurs and haemodynamic symptoms as well as increases in end diastolic pressure and decreases in stroke volume, appeared. After the appearance of the symptoms the sheep were treated symptomatically to delay the development of the cardiomyopathy. The changes in haemodynamic parameters before and after treatment were used and correlated with the intensity of the gallop sounds on a 6 point criterium scale. The results in brief show that, for gallop sound intensities between 0 and 6 on the criterium scale, most of the haemodynamic parameters correlate with the intensity of the gallop sounds, except the cardiac output, cardiopulmonary blood volume and the systemic and pulmonary vascular resistances. The haemodynamic parameters correlate better with the intensities of the gallop rhythm between 0 and 3. It is evident from this study that the model of heart failure in sheep is useful to study heart sounds and may also be valuable in the study of the genesis of the gallop sound. en
dc.description.librarian lmchunu2014 en
dc.description.librarian mn2014
dc.identifier.citation Pretorius, PJ, Van Rooyen, JM, Van Ryssen, JCJ & Minnaar, JP 1988, 'Experimental gallop rhythm in sheep with Gousiekte : correlation of changes in amplitude with haemodynamic parameters', Onderstepoort Journal of Veterinary Research, vol. 55, no. 4, pp. 221-225. en
dc.identifier.issn 0330-2465
dc.identifier.uri http://hdl.handle.net/2263/42386
dc.language.iso en en
dc.publisher Published by the Government Printer, Pretoria. en
dc.rights ©ARC - Onderstepoort and Faculty of Veterinary Science, University of Pretoria (original). ©University of Pretoria. Dept. of Library Services (digital). en
dc.subject Veterinary medicine en
dc.subject.lcsh Veterinary medicine -- South Africa
dc.title Experimental gallop rhythm in sheep with Gousiekte : correlation of changes in amplitude with haemodynamic parameters en