Implementation research : a protocol for two three-arm pragmatic randomised controlled trials on continuous glucose monitoring devices in people with type 1 diabetes in South Africa and Kenya

dc.contributor.authorMarban-Castro, Elena
dc.contributor.authorMuhwava, Lorrein
dc.contributor.authorKamau, Yvonne
dc.contributor.authorSafary, Elvis
dc.contributor.authorRheeder, Paul
dc.contributor.authorKarsas, Maria
dc.contributor.authorKemp, Tanja
dc.contributor.authorFreitas, Johane
dc.contributor.authorCarrihill, Michelle
dc.contributor.authorDave, Joel
dc.contributor.authorKatambo, Daniel
dc.contributor.authorKimetto, Joan
dc.contributor.authorAllie, Razana
dc.contributor.authorNdungu, Joseph
dc.contributor.authorSigwebela, Ntombi
dc.contributor.authorAkach, Dorcas
dc.contributor.authorGirdwood, Sarah
dc.contributor.authorErkosar, Berra
dc.contributor.authorNichols, Brooke E.
dc.contributor.authorHaldane, Cathy
dc.contributor.authorVetter, Beatrice
dc.contributor.authorShilton, Sonjelle
dc.date.accessioned2024-08-15T09:03:27Z
dc.date.available2024-08-15T09:03:27Z
dc.date.issued2024-05
dc.descriptionAVAILABILITY OF DATA AND MATERIALS : The only individual with access to the full dataset during the conduction of the trial will be the statistician at FIND. At the end of the trial, site-specific data will be made available to the research teams at the trial sites. Reasonable requests for the trial data from academic parties will be considered by the corresponding author, and data may be made available in line with the data-sharing policies of FIND.en_US
dc.description.abstractBACKGROUND : Self-monitoring of glucose is an essential component of type 1 diabetes (T1D) management. In recent years, continuous glucose monitoring (CGM) has provided an alternative to daily fingerstick testing for the optimisation of insulin dosing and general glucose management in people with T1D. While studies have been conducted to evaluate the impact of CGM on clinical outcomes in the US, Europe and Australia, there are limited data available for low- and middle-income countries (LMICs) and further empirical evidence is needed to inform policy decision around their use in these countries. METHODS : This trial was designed as a pragmatic, parallel-group, open-label, multicentre, three-arm, randomised (1:1:1) controlled trial of continuous or periodic CGM device use versus standard of care in people with T1D in South Africa and Kenya. The primary objective of this trial will be to assess the impact of continuous or periodic CGM device use on glycaemic control as measured by change from baseline glycosylated haemoglobin (HbA1c). Additional assessments will include clinical outcomes (glucose variation, time in/below/above range), safety (adverse events, hospitalisations), quality of life (EQ-5D, T1D distress score, Glucose Monitoring Satisfaction Survey for T1D), and health economic measures (incremental cost-effectiveness ratios, quality adjusted life years). DISCUSSION : This trial aims to address the substantial evidence gap on the impact of CGM device use on clinical outcomes in LMICs, specifically South Africa and Kenya. The trial results will provide evidence to inform policy and treatment decisions in these countries. TRIAL REGISTRATION : NCT05944731 (Kenya), July 6, 2023; NCT05944718 (South Africa), July 13, 2023.en_US
dc.description.departmentInternal Medicineen_US
dc.description.departmentPaediatrics and Child Healthen_US
dc.description.departmentSchool of Health Systems and Public Health (SHSPH)en_US
dc.description.librarianhj2024en_US
dc.description.sdgSDG-03:Good heatlh and well-beingen_US
dc.description.sponsorshipFIND, with a grant from The Leona M. and Harry B. Helmsley Charitable Trust.en_US
dc.description.urihttps://trialsjournal.biomedcentral.comen_US
dc.identifier.citationMarbán-Castro, E., Muhwava, L., Kamau, Y. et al. Implementation research: a protocol for two three-arm pragmatic randomised controlled trials on continuous glucose monitoring devices in people with type 1 diabetes in South Africa and Kenya. Trials 25, 331 (2024). https://doi.org/10.1186/s13063-024-08132-7.en_US
dc.identifier.issn1745-6215 (online)
dc.identifier.other10.1186/s13063-024-08132-7
dc.identifier.urihttp://hdl.handle.net/2263/97655
dc.language.isoenen_US
dc.publisherBMCen_US
dc.rights© The Author(s) 2024. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License.en_US
dc.subject(3–10): glucose monitoringen_US
dc.subjectContinuous glucose monitoring (CGM)en_US
dc.subjectType 1 diabetes (T1D)en_US
dc.subjectLow- and middle-income countries (LMICs)en_US
dc.subjectProtocolsen_US
dc.subjectStandard of care (SoC)en_US
dc.subjectRandomised controlled trial (RCT)en_US
dc.subjectSDG-03: Good health and well-beingen_US
dc.titleImplementation research : a protocol for two three-arm pragmatic randomised controlled trials on continuous glucose monitoring devices in people with type 1 diabetes in South Africa and Kenyaen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MarbánCastro_Implementation_2024.pdf
Size:
1.02 MB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: