Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs

dc.contributor.authorGoffart, Laura M.
dc.contributor.authorPrecht, Christina
dc.contributor.authorFosgate, Geoffrey Theodore
dc.contributor.authorMaiolini, Arianna
dc.contributor.authorHettlich, Bianca F.
dc.date.accessioned2023-07-18T05:25:08Z
dc.date.available2023-07-18T05:25:08Z
dc.date.issued2022-10-20
dc.descriptionDATA AVAILABILITY STATEMENT : The raw data supporting the conclusions of this article will be made available by the authors, without undue reservationen_US
dc.description.abstractOBJECTIVE : To evaluate the accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in the canine thoracolumbar vertebral column. STUDY DESIGN : In vitro imaging and anatomic study. ANIMALS : Canine cadaveric thoracolumbar vertebral columns (n = 5). METHODS : Smooth Steinmann pins were inserted bicortically into the thoracolumbar vertebral columns between T10 and L7 using recommended insertion angles. Penetration of the spinal canal was not strictly avoided. After pin placement, end-on fluoroscopy images were obtained of each pin. Pin position was subsequently assessed by four evaluators and determined to either being out of the vertebral canal or in, with the latter being additionally divided into partially or completely penetrating the canal. To assess potential differences in modalities, fluoroscopy images were gray-scale inverted and evaluated again later by the same four individuals. Correct identification of pin position in relationship to the vertebral canal was assessed for both fluoroscopy images. Anatomic preparation of the spines was used for verification of pin position in relation to the spinal canal. Some data from this study were compared with historical data on accuracy using orthogonal radiography and computed tomography (CT). RESULTS : Overall sensitivity and specificity of F to detect vertebral canal penetration was 98.8 % (95% confidence interval (CI), 96.0–99.6) and 98.0% (95% CI, 77.0–99.9), respectively. For Fi, sensitivity and specificity were 97.0% (95% CI, 91.5–99.0) and 98.5% (95% CI, 81.5–99.9) respectively. F exceeded Fi for the sensitivity of detecting pin penetration into the vertebral canal (p = 0.039) but specificities were not different (p = 0.585). When comparing to historical data, the overall accuracy of end-on fluoroscopy (F) and inverted fluoroscopy (Fi) was statistical better than conventional radiographic assessment (p < 0.001). CONCLUSION : End-on fluoroscopy is a highly accurate method for the assessment of pin position in relationship to the thoracolumbar spinal canal in cadaveric dogs. CLINICAL SIGNIFICANCE : End-on fluoroscopy, with or without inversion, is accurate in identifying vertebral canal violation by bicortically placed Steinmann pins. When CT is not available, end-on fluoroscopy might be a valuable imaging modality to determine pin position in the canine vertebral column.en_US
dc.description.departmentProduction Animal Studiesen_US
dc.description.librarianam2023en_US
dc.description.urihttps://www.frontiersin.org/journals/veterinary-scienceen_US
dc.identifier.citationGoffart, L.M., Precht, C., Fosgate, G.T., Maiolini, A. & Hettlich, B.F. (2022) Accuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogs. Frontiers in Veterinary Science 9:982560. DOI: 10.3389/fvets.2022.982560.en_US
dc.identifier.issn2297-1769 (online)
dc.identifier.other10.3389/fvets.2022.982560
dc.identifier.urihttp://hdl.handle.net/2263/91497
dc.language.isofren_US
dc.publisherFrontiers Mediaen_US
dc.rights© 2022 Goffart, Precht, Fosgate, Maiolini and Hettlich. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY).en_US
dc.subjectVertebral columnen_US
dc.subjectCanineen_US
dc.subjectBicortical pinsen_US
dc.subjectAccuracyen_US
dc.subjectFluoroscopyen_US
dc.subjectEnd-onen_US
dc.subjectGray- scale inversionen_US
dc.subjectSDG-03: Good health and well-beingen_US
dc.titleAccuracy of end-on fluoroscopy in predicting implant position in relation to the vertebral canal in dogsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Goffart_Accuracy_2022.pdf
Size:
536.21 KB
Format:
Adobe Portable Document Format
Description:
Article
Loading...
Thumbnail Image
Name:
Goffart_AccuracySupplTabs_2022.docx
Size:
64.5 KB
Format:
Microsoft Word XML
Description:
Supplementary Tables

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: