Assessment of MEKC suitability for residue drug monitoring on pharmaceutical manufacturing equipment

dc.contributor.authorBoca, Madalina Brindusa
dc.contributor.authorPretorius, Etheresia
dc.contributor.authorKgaje, Christopher
dc.contributor.authorApostolides, Zeno
dc.date.accessioned2008-04-11T13:52:01Z
dc.date.available2008-04-11T13:52:01Z
dc.date.issued2008-03
dc.description.abstractThe suitability of micellar electrokinetic chromatography for the simultaneous trace determination of several compounds (sulfamethoxazole, trimethoprim, sulfanilic acid, sulfanilamide, 3,4,5-trimethoxybenzoic acid and nonoxynol-9) was assessed. The mixture was separated within 14 min at an applied voltage of 22 kV by using 30 mM phosphate electrolyte, containing 10 mM SDS, adjusted to pH 7.8. Under optimized separation conditions acceptable levels of linearity, precision and accuracy were obtained for all compounds. The method could be used as part of a cleaning validation study when assaying trace levels of co-trimoxazole drug, some of its decomposition products and detergent in the swab samples collected from pharmaceutical manufacturing equipment, after cleaning.en
dc.description.sponsorshipThe Specialty and Fine Chemicals Program, CSIR, South Africa is greatly acknowledged for providing the CE instrument. Furthermore, the first author would like to thank Roche Products (Pty) Ltd. Isando for partially sponsoring this work, and to Mr. Jan Grace of Chemetrix for providing technical assistance.en
dc.format.extent247960 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.citationBoca, MB, Pretorius, E, Kgaje, C & Apostolides, Z 2008, 'Assessment of MEKC suitability for residue drug monitoring on pharmaceutical manufacturing equipment', Journal of Pharmaceutical and Biomedical Analysis, vol. 46, no. 4, pp. 631-638. [http://www.sciencedirect.com/science/journal/07317085]en
dc.identifier.issn0731-7085
dc.identifier.other10.1016/j.jpba.2007.11.022
dc.identifier.urihttp://hdl.handle.net/2263/4961
dc.language.isoenen
dc.publisherElsevieren
dc.rightsElsevieren
dc.subject3,4,5-Trimethoxybenzoic aciden
dc.subjectAntibacterial drugen
dc.subjectCleaning validationen
dc.subjectCo-trimoxazoleen
dc.subjectMEKCen
dc.subjectNonoxynol-9en
dc.subjectSulfamethoxazoleen
dc.subjectSulfanilic aciden
dc.subjectTrimethoprimen
dc.subject.lcshSulfamethoxazole
dc.subject.lcshTrimethoprim
dc.subject.lcshNonoxynol-9
dc.subject.lcshCo-trimoxazole
dc.subject.meshChromatography, Micellar Electrokinetic Capillary
dc.subject.meshSulfanilic Acids
dc.subject.meshsulfanilamide
dc.subject.mesh3,4,5-trimethoxybenzoic acid
dc.titleAssessment of MEKC suitability for residue drug monitoring on pharmaceutical manufacturing equipmenten
dc.typePostprint Articleen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Boca_Assessment(2008).pdf
Size:
242.15 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.39 KB
Format:
Item-specific license agreed upon to submission
Description: