Effects of vibration on pool boiling heat transfer from a vertically aligned array of heated tubes

Show simple item record

dc.contributor.author Noori Rahim Abadi, Seyyed Mohammad Ali
dc.contributor.author Ahmadpour, Ali
dc.contributor.author Meyer, Josua P.
dc.date.accessioned 2019-07-02T08:45:11Z
dc.date.issued 2019-09
dc.description.abstract In the present study, the use of mechanical vibration for the enhancement of pool boiling heat transfer is evaluated theoretically. For this purpose, a vertical array of vibrating circular tubes is considered. The array is submerged in a pool of water under atmospheric conditions and electrically heated for boiling to occur on the tube surfaces. To model this phase-change phenomenon, a two-fluid formulation is employed and accompanied by the Rensselaer Polytechnic Institute (RPI) model to estimate the boiling heat flux on a solid surface. A comprehensive parametric study is undertaken to investigate the effects of the amplitude and frequency of vibration, the magnitude of the heat flux, and the pitch-to-diameter ratio of the array on pool boiling heat transfer in the presence of mechanical vibration. An increase of up to 90% in the heat transfer rate is achieved within the simulated operating conditions. en_ZA
dc.description.department Mechanical and Aeronautical Engineering en_ZA
dc.description.embargo 2020-09-01
dc.description.librarian hj2019 en_ZA
dc.description.uri http://www.elsevier.com/locate/ijmulflow en_ZA
dc.identifier.citation Abadi, S.M.A.N.R., Ahmadpour, A. & Meyer, J.P. 2019, 'Effects of vibration on pool boiling heat transfer from a vertically aligned array of heated tubes', International Journal of Multiphase Flow, vol. 118, pp. 97-112. en_ZA
dc.identifier.issn 0301-9322 (print)
dc.identifier.issn 1879-3533 (online)
dc.identifier.other 10.1016/j.ijmultiphaseflow.2019.06.006
dc.identifier.uri http://hdl.handle.net/2263/70348
dc.language.iso en en_ZA
dc.publisher Elsevier en_ZA
dc.rights © 2019 Elsevier Ltd. All rights reserved . Notice : this is the author’s version of a work that was accepted for publication in International Journal of Multiphase Flow. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in International Journal of Multiphase Flow, vol. 118, pp. 97-112, 2019, doi : 10.1016/j.ijmultiphaseflow.2019.06.006. en_ZA
dc.subject Mechanical vibration en_ZA
dc.subject Pool boiling en_ZA
dc.subject Tube array en_ZA
dc.subject Two-fluid formulation en_ZA
dc.title Effects of vibration on pool boiling heat transfer from a vertically aligned array of heated tubes en_ZA
dc.type Postprint Article en_ZA