Measuring distortion of skeletal elements in Lodox Statscan-generated images

Show simple item record

dc.contributor.author Stull, Kyra Elizabeth
dc.contributor.author L'Abbe, Ericka Noelle
dc.contributor.author Steiner, Stef
dc.date.accessioned 2013-10-23T10:24:20Z
dc.date.available 2014-10-01T00:20:05Z
dc.date.issued 2013-09
dc.description.abstract Due to a scarcity of available skeletal material, anthropologists and other practitioners face difficulties with either the creation or validation of techniques used to estimate a biological profile in subadults. To address this problem, radiographic images of living individuals are often used in lieu of dry skeletal elements. However, radiographic images suffer from distortion. Some problems with metric analyses when using radiographic images may be addressed with the Lodox Statscan, an X-ray machine that claims to produce minimal distortion along the scan-axis due to a linear slot-scanning design. The purpose of this research was to measure the distortion of skeletal elements in radiographic images generated from a Lodox Statscan. Skeletal elements subject to multiple imaging variables that affect distortion were radiographed, measured, and then compared to the dry bone measurements through multiple approaches. An 85% percent agreement within a ±1 mm range and a 97% agreement within a ±2 mm range was obtained. Percent difference results demonstrate that slot-axis measurements incurred more distortion than scan-axis measurements (11.8% and 2.7%, respectively). Inclusion of foam results in 4.5% more error than when foam is not included in the image. Angled scan-axis measurements also incurred more distortion than either nonangled slot- and scan-axis measurements. A Bland-Altmanplot reveals an overall agreement between the radiographic and dry bonemeasurements, with most measurements falling within the upper and lower limits. Similar measurement error is found in Statscan radiographic and dry bone measurements; therefore, the Statscan offers a radiographic venue to collect metric data en_US
dc.description.librarian hb2013 en_US
dc.description.uri http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2353 en_US
dc.identifier.citation Stull, KE, L'Abbe, EN & Steiner, S 2013, 'Measuring distortion of skeletal elements in Lodox Statscan-generated images', Clinical Anatomy Vol. 26, no. 6, pp. 780-786. en_US
dc.identifier.issn 0897-3806 (print)
dc.identifier.issn 1098-2353 (online)
dc.identifier.other 10.1002/ca.22225
dc.identifier.uri http://hdl.handle.net/2263/32137
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.rights © 2013 Wiley Periodicals Inc. This is the pre-peer reviewed version of the following article : Stull, KE, L'abbe, EN & Steiner, S 2013, ' Measuring distortion of skeletal elements in Lodox Statscan-generated images', Clinical Anatomy , vol. 26, no. 6, pp. 780-786,which has been published in final form at http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2353. en_US
dc.subject Radiographs en_US
dc.subject Precision en_US
dc.subject Percent difference en_US
dc.title Measuring distortion of skeletal elements in Lodox Statscan-generated images en_US
dc.type Postprint Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record