Incremental exercise test performance with and without a respiratory gas collection system

Show simple item record

dc.contributor.author Clark, James R.
dc.contributor.author Clark, Jimmy R.
dc.date.accessioned 2009-05-28T12:14:01Z
dc.date.available 2009-05-28T12:14:01Z
dc.date.issued 2008
dc.description.abstract OBJECTIVE: Despite their widespread use in exercise testing, few data are available on the effect of wearing respiratory gas collection (RGC) systems on exercise test performance. Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow resistance and/or discomfort when compared with RGC facemasks, but whether performance decrements exist for RGC facemask wear versus non-wear is unclear. The objective of this study was to evaluate the difference in incremental exercise test performance with and without a RGC system. DESIGN: Twenty moderately active males (age 21.0 ± 1.9 years; VO2peak 55.9 ± 3.0 ml∙kg-1∙min-1) performed two progressive treadmill tests to volitional exhaustion. In random order subjects ran with (MASK) or without (NO-MASK) a RGC facemask and flow sensor connected to a gas analyzer. Descriptive data (mean ± SD) were determined for all parameters. The Wilcoxon signed rank test for paired differences was used to assess mean differences between MASK and NO-MASK conditions. RESULTS: Exercise time to exhaustion, peak treadmill speed, peak blood lactate concentration, peak heart rate and rating of perceived exertion (RPE) were not different (p>0.05) between MASK and NO-MASK conditions. CONCLUTIONS: Incremental exercise test performance is not adversely affected by RGC and analysis equipment, at least in short duration progressive treadmill exercise. Respiratory gas analysis during exercise testing for diagnostic, performance assessment or training prescription purposes would appear to be unaffected by RGC systems. en_US
dc.identifier.citation Clark, JR 2008, ‘Incremental exercise test performance with and without a respiratory gas collection system,’ South African Journal of Sports Medicine, vol. 20, no. 2, pp. 44-48. [http://www.journals.co.za/sama/m_sajsm.html] en_US
dc.identifier.issn 1015-5163
dc.identifier.uri http://hdl.handle.net/2263/10248
dc.language.iso en en_US
dc.publisher Health and Medical Publishing Group en_US
dc.rights Health and Medical Publishing Group en_US
dc.subject Performance en_US
dc.subject Increased respiratory en_US
dc.subject.lcsh Treadmill exercise tests en
dc.subject.lcsh Exercise -- Physiological aspects en
dc.subject.lcsh Respiratory gas monitoring en
dc.title Incremental exercise test performance with and without a respiratory gas collection system en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record