Coetzee, Gert LouisNel, Johannes J.Kat, Cor-JacquesCoetzee, Gert Louis2016-08-022016-08-022015-08-20http://hdl.handle.net/2263/56175Poster presented at the University of Pretoria, Faculty of Veterinary Science Faculty Day, August 20, 2015, Pretoria, South Africa.Created in CoralDRAW X5. PDF size: 5.83 MB.Biomechanical comparison of two internal spinal fixation techniques, applied to a surgically simulated complete spinal injury at L7-S1 was conducted. The study objective was to compare the stability provided by the two fixation techniques to the fracture-luxation.1 poster : color photosPDF fileen©University of Pretoria. Faculty of Veterinary Science (Original and digital). Provided for educational purposes only. It may not be downloaded, reproduced, or distributed in any format without written permission of the original copyright holder. Any attempt to circumvent the access controls placed on this file is a violation of copyright laws and is subject to criminal prosecution. Please contact the collection administrator for copyright issues.Lumbosacral jointSpinal fixationBiomechanical comparisonImplant stabilityVeterinary medicine -- PostersVeterinary orthopedicsInternal fixation in fracturesDogs -- FracturesBiomechanical comparison between pins - polymethylmethacrylate to the “String of Pearls” interlocking plate system (SOP) to stabilize canine lumbosacral fracture-luxationPresentation