Schoeman, J.J. (Jakob Johannes)Du Plessis, Monuko2017-03-172016-10Schoeman, J & Du Plessis, M 2016, 'An analytic model employing an elliptical surface area to determine the gaseous thermal conductance of uncooled VOx microbolometers', Sensors and Actuators, A : Physica', vol. 250, pp. 229-2360924-424710.1016/j.sna.2016.09.033http://hdl.handle.net/2263/59462This work presents a detailed overview ofthe analytic methods for calculating the beam and gaseous thermal conductance components associated with uncooled VOx microbolometers. The conventional method to calculate the gaseous component relies on the assumption that the entire plate is maintained at a uniform temperature,thus the surface area ofthe plate is used for the calculation. We have observed using an industry leading multiphysics simulator thatthis assumption is not strictly true for VOx microbolometers as the conduction pattern exhibits an elliptical shape. Based on this, we have developed and propose an analyticmethod that employs anelliptical surface area scaledappropriately withthedevice dimensions to obtain an estimate ofthe average temperature conduction pattern. Prototype devices were manufactured and experimentally characterised. The devices exhibit thermal conduction characteristics comparable to those in literature and industry, and we could achieve 0.5 W/K under vacuum conditions and 15 W/K at atmospheric pressure with a TCR of −1%/K. However, both simulated and experimental result sets of the gaseous thermal conductance exhibit large deviations from the conventional analytic method, on average approximately 40%. The proposed method reduces this average error significantly to less than 10% when compared to the simulated results.en© 2016 Elsevier B.V. All rights reserved. Notice : this is the author’s version of a work that was accepted for publication in Sensors and Actuators, A : Physical. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Sensors and Actuators, A : Physical, vol. 250, pp. 229-236, 2016. doi : 10.1016/j.sna.2016.09.033.Elliptical area modelThermal conductanceMicrobolometersMEMSAn analytic model employing an elliptical surface area to determine the gaseous thermal conductance of uncooled VOx microbolometersPostprint Article