Mundia, SitwalaStander, Tinus2025-05-222025-05-222025-02S. Mundia and T. Stander, "18–45-GHz Sideband-Separating Downconverter With RF Image Rejection Calibration," in IEEE Microwave and Wireless Technology Letters, vol. 35, no. 2, pp. 237-240, Feb. 2025, doi: 10.1109/LMWT.2024.3514321.2771-9588 (online)2771-957X (print)10.1109/LMWT.2024.3514321http://hdl.handle.net/2263/102463We present a sideband separating downconverter for radio astronomy applications, featuring radio frequency image rejection calibration for frequencies between 18 and 45 GHz. The multichip module optimizes image rejection for specific target observation frequencies by injecting a modulated portion of the Q-branch signal into the I-branch with independent upper and lower sideband injection control. Measurements demonstrate an average image rejection ratio improvement of 9 dB over a 7-GHz band of interest compared with a baseline uncalibrated operation, with improvement of over 40 dB in targeted subbands.en© Copyright 2025 IEEE - All rights reserved, including rights for text and data mining and training of artificial intelligence and similar technologies.CalibrationAmplitude modulationUniversal serial busReceiversRadio frequencyAttenuatorsVectorsMixersRadio astronomyGainImage rejectionMillimeter-wave technologyMultichip modules (MCM)Sideband separation18-45-GHz sideband-separating downconverter with RF image rejection calibrationPostprint Article