A short, reliable, highly reproducible complement fixation test for the serological diagnosis of contagious equine metritis
Loading...
Date
Authors
Herr, S.
Brett, O.L.
Journal Title
Journal ISSN
Volume Title
Publisher
Published by the Government Printer, Pretoria.
Abstract
A complement fixation test, using round-bottomed microtitration plates and an 8 channel microdiluter, based on that used for brucellosis by Herr, Huchzermeyer, Te Brugge, Williamson, Roos & Schiele, 1985, has been developed for use on the sera of horses to detect antibodies to the contagious equine metritis organism. The results with 2 known positive sera tested 116 times in 27 separate tests were reproducible for the most part within a two fold range. They seldom exceeded these limits and never exceeded a fourfold range. The test itself is capable of being carried out within 90 min. The test was slightly more sensitive when sera were inactivated in a hot air oven for 50 min at 58 °C, as compared to inactivation at 62 °C in a water-bath for 50 min. There were no false negative or false positive reactions and no anticomplementary activity in the sera tested.
Description
The articles have been scanned in colour with a HP Scanjet 5590; 600dpi.
Adobe Acrobat XI Pro was used to OCR the text and also for the merging and conversion to the final presentation PDF-format.
Keywords
Veterinary medicine
Sustainable Development Goals
Citation
Gummow, B, Herr, S & Brett, OL 1986, 'A short, reliable, highly reproducible complement fixation test for the serological diagnosis of contagious equine metritis’, Onderstepoort Journal of Veterinary Research, vol. 53, no. 4, pp. 241-243.