Active converter based on the VIENNA rectifier topology interfacing a three-phase generator to a DC-bus

dc.contributor.advisorGitau, Michael Njorogeen
dc.contributor.emailcobus.visser@kentron.co.zaen
dc.contributor.postgraduateVisser, Jacobus Hendriken
dc.date.accessioned2013-09-07T14:44:07Z
dc.date.available2007-11-22en
dc.date.available2013-09-07T14:44:07Z
dc.date.created2007-04-18en
dc.date.issued2007-11-22en
dc.date.submitted2007-10-25en
dc.descriptionDissertation (MEng (Electrical Engineering))--University of Pretoria, 2007.en
dc.description.abstractAC-DC converters find application in every day life as a front-end to DC-DC and DC-AC converters. Active three-phase converters shape the three-phase input current to be sinusoidal and to be in-phase with the input voltage, as well as to provide a steady DC output voltage. This thesis investigates various active three-phase rectifier and control topologies and identifies a rectifier and control topology most suitable for use in converting a variable voltage variable frequency generator output to a DC voltage. In this dissertation, design relations are derived for determining the plant transfer response (for the suitable topology/controller), design equations are derived for designing/choosing the filter components, and guidelines are derived that will assist in choosing the right semi-conductor components and to give an estimation of expected system efficiency. The dissertation investigates the implementation of both analogue and digital control and provides implementation methodologies for both controllers. Expected results are verified by simulation and a build-up prototype. It was shown that the VIENNA rectifier is able to convert a generator type input, with variable input voltage amplitude and variable frequency, to a constant DC-bus voltage whilst controlling the input current to be sinusoidal and in phase with the input voltage. The rectifier was able to maintain a constant DC voltage at the output for input voltages as low as half the rated input voltage and for an equivalent output power of half the rated output power. This suggests that the VIENNA rectifier, controlled as a dual-boost rectifier, is suitable for applications that require power factor corrections and simultaneously operate from a wide input voltage range.en
dc.description.availabilityunrestricteden
dc.description.degreeMEng
dc.description.departmentElectrical, Electronic and Computer Engineeringen
dc.identifier.citationVisser, JH 2007, Active converter based on the VIENNA rectifier topology interfacing a three-phase generator to a DC-bus, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/29031>
dc.identifier.otherPretoriaen
dc.identifier.upetdurlhttp://upetd.up.ac.za/thesis/available/etd-10252007-163633/en
dc.identifier.urihttp://hdl.handle.net/2263/29031
dc.language.isoen
dc.publisherUniversity of Pretoriaen_ZA
dc.rights© University of Pretoren
dc.subjectRectifieren
dc.subjectViennaen
dc.subjectDc-voltageen
dc.subjectGeneratoren
dc.subjectThree-phaseen
dc.subjectConstant frequencyen
dc.subjectAnalogue controlen
dc.subjectDeratingen
dc.subjectDigital controlen
dc.subjectModal analysisen
dc.subjectPower factor correction.en
dc.subjectUCTDen_US
dc.titleActive converter based on the VIENNA rectifier topology interfacing a three-phase generator to a DC-busen
dc.typeDissertationen