Preliminary assessment of the fluid-structure interaction effects in a GEN IV LMR

dc.contributor.authorLo Frano, R.
dc.contributor.authorForasassi, G.
dc.date.accessioned2014-12-15T07:42:17Z
dc.date.available2014-12-15T07:42:17Z
dc.date.issued2012
dc.description.abstractPaper presented at the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_ZA
dc.description.abstractThe devastating Fukushima 2011 earthquake and tsunami and their consequent multi-reactor damages in Japan, mainly due to the hydrodynamic effects arisen from the fluid-structure interaction, had a significant impact on the global nuclear energy industry. These events highlighted the need to design the future/existing nuclear installations in order to be able to assure a huge safety level in reference accident configuration and, also, in beyond design conditions. In this framework it is extremely important to analyze the lessons learnt from the Fukushima events and to evaluate the safety margins of the nuclear power plants in particular, under ongoing unexpected severe earthquake, such as a beyond design basis one (BDBE). The aim of this paper deals with the evaluation of the dynamic effects seismically induced by the fluid-structure interaction in an under development Gen IV Liquid Metal Reactor (LMR), specifically with reference to the European reactor configuration. The fluid-structure interaction and sloshing phenomena were numerically analyzed taking into account the non linearities and instabilities due to the influence of material and geometrical parameters. In order to attain the mentioned goal a suitable numerical procedure based on an external coupling between dynamic and structural codes (as MSC.Dytran and MARC) was applied, setting up a detailed 3-D FEM model as well as implementing a specific algorithm capable to analyze the coupling effects between the considered fluid and the structures and the sloshing phenomenon. Numerical results were presented and discussed highlighting the importance of the fluid-structure interaction effects in terms of stress intensity as well as the capacity of internals and vessel walls to withstand wave’s impacts.en_ZA
dc.description.librariandc2014en_ZA
dc.format.extent8 pagesen_ZA
dc.format.mediumPDFen_ZA
dc.identifier.citationLo Frano, R & Forasassi, G 2012, Preliminary assessment of the fluid-structure interaction effects in a GEN IV LMR, Paper presented to the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_ZA
dc.identifier.isbn9781868549863
dc.identifier.urihttp://hdl.handle.net/2263/43014
dc.language.isoenen_ZA
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_ZA
dc.relation.ispartofHEFAT 2012en_US
dc.rightsUniversity of Pretoriaen_ZA
dc.subjectFukushima 2011 earthquakeen_ZA
dc.subjectMulti-reactor damagesen_ZA
dc.subjectHydrodynamic effectsen_ZA
dc.subjectFluid-structure interaction (FSI)en_ZA
dc.subjectBeyond design basis one (BDBE)en_ZA
dc.subjectGen IV liquid metal reactoren_ZA
dc.subjectMSC.Dytranen_ZA
dc.subjectMARCen_ZA
dc.subject3-D FEM modelen_ZA
dc.titlePreliminary assessment of the fluid-structure interaction effects in a GEN IV LMRen_ZA
dc.typePresentationen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
lo_frano_preliminary_2014.pdf
Size:
746.49 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: