Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers

dc.contributor.authorKennedy, I.J.
dc.contributor.authorSpence, S.W.T.
dc.contributor.authorSpratt, G.R.
dc.date.accessioned2014-12-15T07:22:50Z
dc.date.available2014-12-15T07:22:50Z
dc.date.issued2012
dc.description.abstractPaper presented at the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_ZA
dc.description.abstractThe purpose of this study is to determine the influence of inclining the heat exchanger relative to the fan in a forced- draught air-cooled heat exchanger. Since inclination increases plenum depth, the effect of inclination is also compared with increasing plenum depth without inclination. The experimental study shows that inclination improves thermal performance by only 0.5%, when compared with a baseline non-inclined case with a shallow plenum. Similarly, increasing plenum depth without inclination has a thermal performance benefit of approximately 1%. The numerical study shows that, as the heat exchanger is inclined, the low velocity core at the centre of the heat exchanger moves to one side.en_ZA
dc.description.librariandc2014en_ZA
dc.format.extent8 pagesen_ZA
dc.format.mediumPDFen_ZA
dc.identifier.citationKennedy, IJ, Spence, SWT & Spratt, GR 2012, Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers, Paper presented to the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_ZA
dc.identifier.isbn9781868549863
dc.identifier.urihttp://hdl.handle.net/2263/42969
dc.language.isoenen_ZA
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_ZA
dc.relation.ispartofHEFAT 2012en_US
dc.rightsUniversity of Pretoriaen_ZA
dc.subjectInclining the heat exchanger relative to the fanen_ZA
dc.subjectPlenum depthen_ZA
dc.subjectForced- draught air-cooled heat exchangersen_ZA
dc.titleInvestigation of heat exchanger inclination in forced-draught air-cooled heat exchangersen_ZA
dc.typePresentationen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
kennedy_investigation_2014.pdf
Size:
736.02 KB
Format:
Adobe Portable Document Format
Description:
Investigation of heat exchanger inclination in forced-draught air-cooled heat exchangers

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: