Inter- and intra-laboratory variability of CD4 cell counts in Swaziland
dc.contributor.author | Mlawanda, Ganizani | |
dc.contributor.author | Rheeder, Paul | |
dc.contributor.author | Miot, Jacqui | |
dc.date.accessioned | 2012-07-02T12:00:35Z | |
dc.date.available | 2012-07-02T12:00:35Z | |
dc.date.issued | 2012-06 | |
dc.description.abstract | BACKGROUND: Analytical variability in CD4 enumeration is well known, but few studies from southern Africa have quantified the inter- and intra-laboratory variability in CD4 count measurements. In addition, the possible impact of time lapse after sample collection on CD4 reliability is not well understood. METHODS: A cross-sectional study was conducted at Royal Swaziland Sugar Corporation Hospital and three laboratories, Lab A (comparator), Lab B (national reference) and Lab C (rural hospital). Blood from HIV-infected individuals was collected using routine venepuncture into separate specimens for each of the three laboratories. The samples were further subdivided at each laboratory: one was run at 12 hours and the second at 24 hours after venepuncture. The results of absolute CD4 count and CD4 percentage testing were compared within (intra-laboratory) and between (inter-laboratory) laboratories. RESULTS: Among 53 participants, the mean CD4 count at 12 hours was 373 cells/μl, 396 cells/μl and 439 cells/μl, and at 24 hours 359 cells/μl, 389 cells/ μl and 431 cells/μl, for laboratories A, B and C, respectively. The coefficient of intra-laboratory variation was 4%, 8% and 20% for CD4 count for laboratories A, B and C, respectively. Comparing 12- and 24-hour measurements, the mean difference (bias) within the laboratories between the two time points (and limits of agreement, LOAs) was 14 (-46 to 73), 8 (-161 to 177) and 7 (20 to 33) cells/μl for labs A, B and C, respectively. Comparing Lab A versus Lab B, lab A versus Lab C and Lab B versus Lab C, the inter-laboratory bias for the CD4 count at 12 hours was -32, -64 and -38 cells/μl, respectively. The corresponding LOAs were -213 to 150, -183 to 55, and -300 to 224, respectively. At 24 hours, the biases and LOAs were similar to those at 12 hours. CONCLUSIONS: CD4 counts appeared reliable at all three laboratories. Lab B and Lab C were clinically interchangeable with the comparator laboratory, Lab A, but not between themselves. Time to measurement does not affect the interlaboratory agreement within 12 and 24 hours. | en_US |
dc.description.sponsorship | A University of Pretoria RESCOM grant partially covered the laboratory costs during the study. | en_US |
dc.description.uri | http://www.sajhivmed.org.za | en_US |
dc.identifier.citation | Mlawanda, G, Rheeder, P & Miot, J 2012, 'Inter- and intra-laboratory variability of CD4 cell counts in Swaziland', Southern African Journal of HIV Medicine, vol. 13, no. 2, pp. 59-63. | en_US |
dc.identifier.issn | 1608-9693 (print) | |
dc.identifier.issn | 2078-5151 (online) | |
dc.identifier.uri | http://hdl.handle.net/2263/19287 | |
dc.language.iso | en | en_US |
dc.publisher | Health and Medical Publishing Group | en_US |
dc.rights | Health and Medical Publishing Group | en_US |
dc.subject | Swaziland | en_US |
dc.subject | Inter- and intra-laboratory variability | en_US |
dc.subject | CD4 cell counts | en_US |
dc.title | Inter- and intra-laboratory variability of CD4 cell counts in Swaziland | en_US |