Starting transient simulation of a vacuum ejector-diffuser system under Chevron effects

dc.contributor.authorKong, Fanshi
dc.contributor.authorKim, Heuy Dong
dc.date.accessioned2015-04-23T11:25:31Z
dc.date.available2015-04-23T11:25:31Z
dc.date.issued2014
dc.description.abstractPaper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014.en_ZA
dc.description.abstractThe vacuum ejector-diffuser system has been widely used in many applications such as refrigeration systems, high altitude test facilities and fluid transportation devices. In the present study, the starting transient flows of supersonic vacuum ejector-diffuser system, and its performance characteristics were simulated and analyzed by numerical methods. Newly designed chevron lobes were installed at the inlet of the primary stream of the vacuum ejector-diffuser system for the purpose of the performance improvement. A CFD method based on transient scheme has been applied to simulate the equilibrium flows and flow dynamics behavior of the secondary chamber. Primary numerical analysis results show that the chevrons get a positive effect on the vacuum ejector performance: less starting time and secondary chamber equilibrium pressure are found in chevron transient flow, compared with the convergent nozzle. The flow characteristics inside the ejector system are discussed using pressure history, vortices behavior, transient flow pattern and Reynolds stress distributions.en_ZA
dc.description.librariandc2015en_ZA
dc.format.extent5 pagesen_ZA
dc.format.mediumPDFen_ZA
dc.identifier.citationKong, F & Kim, HD 2014, 'Starting transient simulation of a vacuum ejector-diffuser system under Chevron effects', Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014.en_ZA
dc.identifier.isbn97817759206873
dc.identifier.urihttp://hdl.handle.net/2263/44595
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_ZA
dc.rights© 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.en_ZA
dc.subjectVacuum ejector-diffuser systemen_ZA
dc.subjectRefrigeration systemsen_ZA
dc.subjectFluid transportation devicesen_ZA
dc.subjectSupersonic vacuum ejector-diffuser systemen_ZA
dc.subjectChevron lobesen_ZA
dc.subjectFlow dynamicsen_ZA
dc.titleStarting transient simulation of a vacuum ejector-diffuser system under Chevron effectsen_ZA
dc.typePresentationen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kong_Starting_2014.pdf
Size:
691 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: