Management of hydrogen sulphide generation at a Kraft mill effluent plant
dc.contributor.author | Rava, Eleonora Maria Elizabeth | |
dc.contributor.author | Schoeman, J.J. (Jakob Johannes) | |
dc.contributor.author | Allison, P.J. | |
dc.contributor.author | Dilsook, V. | |
dc.contributor.email | emrava@buckman.com | en_US |
dc.date.accessioned | 2009-02-03T12:17:19Z | |
dc.date.available | 2009-02-03T12:17:19Z | |
dc.date.issued | 2008-04 | |
dc.description.abstract | Communities surrounding an integrated Kraft mill noticed odours from the mill’s effluent treatment plant. A project was therefore commissioned by the mill to proactively manage the odours from both the pulp-processing operations and the effluent treatment plant. This project formed part of a co-ordinated study that was implemented by the mill to limit emissions of the total reduced sulphur (TRS) components from the pulp mill operations. It was found that sulphate-reducing bacteria(SRB) converted the sulphates present in the effluent to hydrogen sulphide (H2S) by dissimilatory respiration. The combined use of a nitrate-releasing biomodifier (Bulab® 9518) and an anthraquinone sulphate-reduction inhibitor (Busperse® 2432) was effective in reducing both SRB activity and H2S levels. The average aqueous H2S levels (40 mg/ℓ) were reduced to between 92% and 99%. | en_US |
dc.identifier.citation | Rava, E, Schoeman, JJ, Allison, PJ & Dilsook, V 2008, 'Management of hydrogen sulphide generation at a Kraft mill effluent plant', Water SA, vol. 34, no. 2, pp. 245-248. [http://www.wrc.org.za/publications_watersa.htm] | en_US |
dc.identifier.issn | 0378-4738 | |
dc.identifier.uri | http://hdl.handle.net/2263/8796 | |
dc.language.iso | en | en_US |
dc.publisher | Water Research Council | en_US |
dc.rights | Water Research Council | en_US |
dc.subject | Biomodifiers | en_US |
dc.subject | Hydrogen sulphide | en_US |
dc.subject | Kraft mill effluent plant | en_US |
dc.subject | Sulphate-reducing bacteria (SRB) | en_US |
dc.subject | Anthraquinone | en_US |
dc.subject | Sulphate reduction inhibition | en_US |
dc.subject | Sodium nitrate | en_US |
dc.subject.lcsh | Effluent quality -- Testing | |
dc.subject.lcsh | Factory and trade waste -- Purification | |
dc.title | Management of hydrogen sulphide generation at a Kraft mill effluent plant | en_US |
dc.type | Article | en_US |