Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator

dc.contributor.authorMolepo, Maketo
dc.contributor.authorBarnard, Annette-Christi
dc.contributor.authorBirkholtz, Franz Friedrich
dc.contributor.authorTetsworth, Kevin
dc.contributor.authorGlatt, Vaida
dc.contributor.authorHohmann, Erik
dc.date.accessioned2018-07-17T07:52:03Z
dc.date.issued2018-12
dc.description.abstractPURPOSE : The purpose of this study was to evaluate the clinical and functional outcomes of failed plate fixation in distal tibia fractures salvaged with hexapod circular fixators. MATERIALS AND METHODS : The database of a specialized limb reconstruction center was searched for all patients with failed plate fixation undergoing limb reconstruction with a circular external fixator between 2008 and 2017. Patients between the ages of 18–65 years, with a symptomatic distal tibia malunion or non-union following plate and screw fixation were included. The SF-12 and Foot Function Index (FFI) scoring systems were used to measure clinical and functional outcomes. RESULTS : Ten patients with a mean age of 38 ± 13 years met the inclusion criteria. Seven patients had an infected non-union, two hypertrophic non-unions, and one a malunion. The mean follow-up was 41.7 ± 28.3 months. The mean duration of external fixation was 232.9 ± 146.6 days. The SF-12 demonstrated a mean score of 49.4 ± 7.7 for the physical component and a mean score of 55.3 ± 8.1 for the mental component. Five patients (50%) scored above 45 points for the SF12 physical component, and nine patients (90%) scored above 45 points for the mental component, indicating good outcome can be achieved. The mean FFI score was 24.9 ± 19.9, and six patients had a score below 14 points (good outcome). Radiological union was observed in all 10 patients at a mean of 29 ± 14 months. CONCLUSIONS : The results of this study suggest that hexapod circular external fixation is an attractive surgical alternative for the treatment of failed plate fixation of distal tibial fractures, and can reliably achieve bony union and result in very satisfactory clinical outcomes.en_ZA
dc.description.departmentOrthopaedic Surgeryen_ZA
dc.description.embargo2019-12-01
dc.description.librarianhj2018en_ZA
dc.description.urihttps://link.springer.com/journal/590en_ZA
dc.identifier.citationMolepo, M., Barnard, AC., Birkholtz, F. et al. Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator. EEuropean Journal of Orthopaedic Surgery & Traumatology 2018) 28: 1617-1624. https://doi.org/10.1007/s00590-018-2231-x.en_ZA
dc.identifier.issn1633-8065 (print)
dc.identifier.issn1432-1068 (online)
dc.identifier.other10.1007/s00590-018-2231-x
dc.identifier.urihttp://hdl.handle.net/2263/65766
dc.language.isoenen_ZA
dc.publisherSpringeren_ZA
dc.rights© Springer-Verlag France SAS, part of Springer Nature 2018. The original publication is available at : https://link.springer.com/journal/590.en_ZA
dc.subjectCircular external fixationen_ZA
dc.subjectDistal tibial fracturesen_ZA
dc.subjectHexapoden_ZA
dc.subjectPlate fixationen_ZA
dc.subjectNon-unionen_ZA
dc.titleFunctional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixatoren_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Molepo_Functional_2018.pdf
Size:
360.61 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: