Wideband acoustic immittance for assessing middle ear functioning for preterm neonates in the neonatal intensive care unit

dc.contributor.authorGouws, Nandel
dc.contributor.authorSwanepoel, De Wet
dc.contributor.authorBiagio-de Jager, Leigh
dc.date.accessioned2018-02-16T09:27:35Z
dc.date.available2018-02-16T09:27:35Z
dc.date.issued2017-06-28
dc.description.abstractBACKGROUND : The primary aim of newborn hearing screening is to detect permanent hearing loss. Because otoacoustic emissions (OAEs) and automated auditory brainstem response (AABR) are sensitive to hearing loss, they are often used as screening tools. On the other hand, falsepositive results are most often because of transient outer- and middle ear conditions. Wideband acoustic immittance (WAI), which includes physical measures known as reflectance and absorbance, has shown potential for accurate assessment of middle ear function in young infants. OBJECTIVE : The main objective of this study was to determine the feasibility of WAI as a diagnostic tool for assessing middle ear functioning in preterm neonates in the neonatal intensive care unit (NICU) designed for premature and ill neonates. A further objective was to indicate the difference between the reflectance values of tones and click stimuli. METHOD : Fifty-six at-risk neonates (30 male and 26 female), with a mean age at testing of 35.6 weeks (range: 32–37 weeks) and a standard deviation of 1.6 from three private hospitals, who passed both the distortion product otoacoustic emission (DPOAE) and AABR tests, were evaluated prior to discharge from the NICU. Neonates who presented with abnormal DPOAE and AABR results were excluded from the study. WAI was measured by using chirp and tone stimuli. In addition to reflectance, the reflectance area index (RAI) values were calculated. RESULTS : Both tone and chirp stimuli indicated high-power reflectance values below a frequency of 1.5 kHz. Median reflectance reached a minimum of 0.67 at 1 kHz – 2 kHz but increased to 0.7 below 1 kHz and 0.72 above 2 kHz for the tone stimuli. For chirp stimuli, the median reflectance reached a minimum of 0.51 at 1 kHz – 2 kHz but increased to 0.68 below 1 kHz and decreased to 0.5 above 2 kHz. A comparison between the present study and previous studies on WAI indicated a substantial variability across all frequency ranges. CONCLUSION : These WAI measurements conducted on at-risk preterm NICU neonates (mean age at testing: 35.6 weeks, range: 32–37 weeks) identified WAI patterns not previously reported in the literature. High reflective values were obtained across all frequency ranges. The age of the neonates when tested might have influenced the results. The neonates included in the present study were very young preterm neonates compared to the ages of neonates in previous studies. WAI measured in at-risk preterm neonates in the NICU was variable with environmental and internal noise influences. Transient conditions affecting the soundconduction pathway might have influenced the results. Additional research is required to investigate WAI testing in ears with and without middle ear dysfunction. The findings of the current study imply that in preterm neonates it was not possible to determine the feasibility of WAI as a diagnostic tool to differentiate between ears with and without middle ear pathology.en_ZA
dc.description.departmentSpeech-Language Pathology and Audiologyen_ZA
dc.description.librarianam2018en_ZA
dc.description.urihttp://www.sajcd.org.za/index.php/SAJCDen_ZA
dc.identifier.citationGouws, N., Swanepoel, D.W., & De Jager, L.B. (2017). Wideband acoustic immittance for assessing middle ear functioning for preterm neonates in the neonatal intensive care unit. South African Journal of Communication Disorders 64(1), a182. https://doi.org/ 10.4102/sajcd.v64i1.182.en_ZA
dc.identifier.issn0379-8046 (print)
dc.identifier.issn2225-4765 (online)
dc.identifier.other10.4102/sajcd.v64i1.182
dc.identifier.urihttp://hdl.handle.net/2263/64011
dc.language.isoenen_ZA
dc.publisherAOSIS OpenJournalsen_ZA
dc.rights© 2017. The Authors. Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License.en_ZA
dc.subjectHearing lossen_ZA
dc.subjectScreening toolsen_ZA
dc.subjectInfantsen_ZA
dc.subjectNewborn hearing screeningen_ZA
dc.subjectOtoacoustic emission (OAE)en_ZA
dc.subjectAutomated auditory brainstem response (AABR)en_ZA
dc.subjectWideband acoustic immittance (WAI)en_ZA
dc.subjectNeonatal intensive care unit (NICU)en_ZA
dc.subjectMiddle ear functioningen_ZA
dc.subjectPreterm neonatesen_ZA
dc.subjectReflectance values of tonesen_ZA
dc.subjectClick stimulien_ZA
dc.titleWideband acoustic immittance for assessing middle ear functioning for preterm neonates in the neonatal intensive care uniten_ZA
dc.typeArticleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gouws_Wideband_2017.pdf
Size:
2.83 MB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: