Effects of slip on eccentrically loaded multiple-ply girder timber trusses
dc.contributor.author | Burdzik, W.M.G. | |
dc.contributor.author | Skorpen, Sarah Anne | |
dc.contributor.author | Jansen van Rensburg, Karin | |
dc.contributor.email | sarah.skorpen@up.ac.za | en_US |
dc.date.accessioned | 2014-07-04T06:08:18Z | |
dc.date.available | 2014-07-04T06:08:18Z | |
dc.date.issued | 2014-03 | |
dc.description.abstract | Recent roof failures in South Africa, of multiple ply nail plated trusses, have necessitated a rethink about the way in which timber trusses are analysed. The authors believe that the relative slip between plies caused by a torsional moment as a result of eccentric loading is a possible reason for some of the failures. The design assumption in South Africa and America is that all the plies share the applied load equally; Eurocode 5 (BS EN 1995-1-1:2004) does not cover the design of multiple ply trusses; and BS 5268-3:2006 recommends additional load factors to be applied to eccentrically loaded truss components with the outer ply being loaded more than the inner plies, as a result of the torsion induced by an out-of-plane eccentricity. In this paper, a matrix stiffness method is used to show that, by ignoring the eccentric loading and relative slip between the trusses, the member and plate force may be underestimated by a factor in excess of two for a three ply girder truss. A single three-ply girder truss test is used to illustrate the merits of the method. The required load factors calculated also show that the magnification factors in BS 5268-3:2006 are lower than they should be. | en_US |
dc.description.librarian | hb2014 | en_US |
dc.description.uri | http://www.icevirtuallibrary.com | en_US |
dc.identifier.citation | Burdzik, WMG, Skorpen, SA & Jansen van Rensburg, K 2014, 'Effects of slip on eccentrically loaded multiple-ply girder timber trusses', Proceedings of the ICE - Structures and Buildings, vol. 57, no. 3, pp. 68-71. | en_US |
dc.identifier.issn | 0965-0911(print) | |
dc.identifier.issn | 1751-7702 (online) | |
dc.identifier.other | 10.1680/stbu.12.00034 | |
dc.identifier.uri | http://hdl.handle.net/2263/40536 | |
dc.language.iso | en | en_US |
dc.publisher | Institution of Civil Engineering | en_US |
dc.rights | ICE Publishing : All rights reserved | en_US |
dc.subject | Failures | en_US |
dc.subject | Strength and testing of materials | en_US |
dc.subject | Timber structures | en_US |
dc.title | Effects of slip on eccentrically loaded multiple-ply girder timber trusses | en_US |
dc.type | Postprint Article | en_US |