The accuracy of magnetic resonance imaging diagnosis of non-osseous knee injury at Steve Biko Academic Hospital

dc.contributor.authorSingh, Nashil
dc.contributor.authorHanekom, Heleen
dc.contributor.authorSuleman, Farhana Ebrahim
dc.date.accessioned2020-07-17T12:39:43Z
dc.date.available2020-07-17T12:39:43Z
dc.date.issued2019-09
dc.description.abstractBACKGROUND: Preoperative magnetic resonance imaging (MRI) has internationally been proven to reduce unnecessary knee arthroscopies and assist with surgical planning. This has the advantage of avoiding unnecessary surgery and the associated anaesthetic risk, as well as reducing costs. No data were found in the recently published literature assessing the accuracy of MRI interpretation of knee ligament injury in the public sector locally. OBJECTIVES: This pilot study aimed to determine the accuracy of MRI in detecting non-osseous knee injury in a resource-limited tertiary-level academic hospital in Pretoria, South Africa, compared to the gold standard arthroscopy findings. METHOD: This was an exploratory retrospective analysis of 39 patients who had MRI and arthroscopy at Steve Biko Academic Hospital (SBAH). True positive, true negative, false positive and false negative results were extrapolated from findings in both modalities and translated into sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for each structure. RESULTS: Negative predictive values were recorded as 97%, 81%, 90% and 100% (anterior cruciate ligament [ACL], medial meniscus [MM], lateral meniscus [LM] and posterior cruciate ligament [PCL], respectively), which were comparative to recently published international literature. The PPV results were lower than those previously evaluated at 55%, 58%, 55% and not applicable. The sensitivities and specificities of the ligaments were 83%, 58%, 83% and not applicable; and 87%, 81%, 70% and not applicable, respectively. CONCLUSION: Magnetic resonance imaging was found to be sensitive and specific, with a high NPV noted in all structures evaluated. Negative results can therefore be used to avoid unnecessary surgery to the benefit of the patient and state. The study reiterates that high accuracy can be obtained from MRI on a 1.5-tesla non-dedicated scanner, with interpretation by generalist radiologists.en_ZA
dc.description.departmentRadiologyen_ZA
dc.description.librarianpm2020en_ZA
dc.description.urihttps://sajr.org.zaen_ZA
dc.identifier.citationSingh N, Hanekom H, Suleman FE. The accuracy of magnetic resonance imaging diagnosis of non-osseous knee injury at Steve Biko Academic Hospital. South African Journal of Radiology 2019;23(1), a1754. https://doi.org/10.4102/sajr.v23i1.1754.en_ZA
dc.identifier.issn1027-202X (print)
dc.identifier.issn2078-6778 (online)
dc.identifier.other10.4102/sajr.v23i1.1754
dc.identifier.urihttp://hdl.handle.net/2263/75345
dc.language.isoenen_ZA
dc.publisherAOSIS Open Journalsen_ZA
dc.rights© 2019. The Author(s). Licensee: AOSIS. This is distributed under the terms of the Creative Commons Attribution License.en_ZA
dc.subjectMusculoskeletalen_ZA
dc.subjectMedial meniscusen_ZA
dc.subjectLateral meniscusen_ZA
dc.subjectMagnetic resonance imaging (MRI)en_ZA
dc.subjectAnterior cruciate ligament (ACL)en_ZA
dc.subjectPosterior cruciate ligament (PCL)en_ZA
dc.subjectNon-osseous knee injuryen_ZA
dc.subjectAcademic hospitalen_ZA
dc.subjectPretoriaen_ZA
dc.subjectSteve Biko Academic Hospital (SBAH)en_ZA
dc.titleThe accuracy of magnetic resonance imaging diagnosis of non-osseous knee injury at Steve Biko Academic Hospitalen_ZA
dc.typeArticleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Singh_Accuracy_2019.pdf
Size:
1.47 MB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: