dc.description.abstractPaper presented at the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_US
dc.description.abstractThe combined use of displacement ventilation (DV) [1-2] and a radiant cooling floor (RCF) [3-5] is increasingly common in the field of building climatization. DV systems are based on injecting air directly into the occupied zone of the building, at low speed and at a temperature slightly below the comfort one. On the other hand, RCF systems are based on circulating cold water through a circuit of pipes embedded in the pavement. With this hybrid cooling system (DV+RCF) that combines both technologies [6], only the occupied zone is climatizated and a vertical stratification of the room air temperature is achieved [7]. In addition, indoor air quality is greater than when conventional cooling systems are used [8], because the updraft convection currents caused by heat sources in the occupied zone [9], move the hot air and contaminants to the roof level going through the occupied zone only once. DV+RCF systems work better in building with high ceiling (of 3 meters high or more), where the air stratification will improve the thermal efficiency and pollution control. Therefore, its use is appropriate in large public buildings, for example theatres [10], museums [11], train stations [12] or airport terminals [13], which are characterized by their high rise. Despite the advantages of implementing a DV+RCF system, their behaviour is not well characterized for an efficient dimensioning of the system. Therefore, the aim of this paper is to present two correlations to quantify, on the one hand, the amount of energy (as heat) the floor is able to absorb by convection, that is, the heat flux along the floor, and, on the other hand, the maximum distance of influence of the primary air stream driven by the DV system. These correlations have been found for the hybrid cooling system DV+RCF in a large enclosure, using computational fluid dynamics (CFD). Moreover, they take into account the presence of the cooling floor and the vertical stratification of air temperature in the enclosure, becoming a powerful tool to help in the cooling system dimensioning. Multiple simulations with different Reynolds, based on the size of the diffuser and its supply air flow rate, and Grashof, based on the temperature difference between the floor and the air supplied by the diffuser, numbers were used to obtain the correlations.en_US
dc.description.librariandc2014en_US
dc.format.extent9 pagesen_US
dc.format.mediumPDFen_US
dc.identifier.citationPeña-Suárez, JM & Ortega-Casanova, J 2012, CFD of a hybrid cooling system composed of a displacement ventilation unit and a radiant cooling floor, Paper presented to the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012.en_US
dc.identifier.isbn9781868549863
dc.identifier.urihttp://hdl.handle.net/2263/42683
dc.language.isoenen_US
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_US
dc.relation.ispartofHEFAT 2012en_US
dc.rightsUniversity of Pretoriaen_US
dc.subjectDisplacement ventilation (DV)en_US
dc.subjectRadiant cooling floor (RCF)en_US
dc.subjectBuilding climatizationen_US
dc.subjectDV systemsen_US
dc.subjectRCF systemsen_US
dc.subjectHybrid cooling systemen_US
dc.subjectComputational fluid dynamics (CFD)en_US
dc.subjectDiffuseren_US
dc.titleCFD of a hybrid cooling system composed of a displacement ventilation unit and a radiant cooling flooren_US
dc.typePresentationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pena-suarez_cfd_2014.pdf
Size:
1.55 MB
Format:
Adobe Portable Document Format
Description:
CFD of a hybrid cooling system composed of a displacement ventilation unit and a radiant cooling floor

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: