Adaptive digital distance relay for SSSC‐based double‐circuit transmission line using phasor measurement unit

dc.contributor.authorDhenuvakonda, Koteswara Raju
dc.contributor.authorSingh, Arvind R.
dc.contributor.authorThakre, Mohan P.
dc.contributor.authorKarasani, Raghavendra Reddy
dc.contributor.authorNaidoo, Raj
dc.date.accessioned2019-06-26T13:41:16Z
dc.date.issued2019-04
dc.description.abstractThe existence of midpoint series flexible alternating current transmission system (FACTS) devices leads to degrade the performance of mho relay, leading in erroneous estimation of fault location, ie, overreach or underreach for wide variation in network parameters. This research article proposes a novel mho relay algorithm to improve the performance of distance relay in presence of FACTS device using phasor measurement unit (PMU). First, the complete model of transmission system employing static synchronous series compensator (SSSC) and its control strategy is described analytically, where the error introduced in measurement of impedance due to SSSC on the performance of distance relay. Second, a novel mho relay procedure is developed based on PMU to protect the first zone of double‐circuit transmission line for single line‐to‐ground (SLG) fault. The proposed work is analysed and simulated with 48‐pulse SSSC carried out with Bergeron model of transmission line using power system computer‐aided design (PSCAD) computer simulation. Finally, the simulation results represent that the suggested adaptive scheme is truthful, reliable, and secure with change in compensation level of SSSC.en_ZA
dc.description.departmentElectrical, Electronic and Computer Engineeringen_ZA
dc.description.embargo2020-04-01
dc.description.librarianhj2019en_ZA
dc.description.urihttp://wileyonlinelibrary.com/journal/etepen_ZA
dc.identifier.citationDhenuvakonda KR, Singh A, Thakre MP, Karasani RR, Naidoo R. Adaptive digital distance relay for SSSC based double circuit transmission line using phasor measurement unit. International Transactions on Electrical Energy Systems 2019;29:e2787. https://doi.org/10.1002/etep.2787.en_ZA
dc.identifier.issn2050-7038 (online)
dc.identifier.other10.1002/etep.2787
dc.identifier.urihttp://hdl.handle.net/2263/70313
dc.language.isoenen_ZA
dc.publisherWileyen_ZA
dc.rights© 2018 John Wiley & Sons, Ltd. This is the pre-peer reviewed version of the following article : Adaptive digital distance relay for SSSC based double circuit transmission line using phasor measurement unit, International Transactions on Electrical Energy Systems, vol. 29, no. 6, art. e2787, pp. 1-20, 2019, doi : 10.1002/etep.2787. The definite version is available at : http://wileyonlinelibrary.com/journal/etep.en_ZA
dc.subjectProtectionen_ZA
dc.subjectCompensatoren_ZA
dc.subjectShunten_ZA
dc.subjectAlgorithmen_ZA
dc.subjectAdaptive distance relayen_ZA
dc.subjectStatic synchronous series compensator (SSSC)en_ZA
dc.subjectPhasor measurement unit (PMU)en_ZA
dc.subjectPower system protectionen_ZA
dc.subjectPower system computer‐aided design (PSCAD)en_ZA
dc.subjectElectro magnetic transient design and control (EMTDC)en_ZA
dc.subjectFlexible alternating current transmission system (FACTS)en_ZA
dc.titleAdaptive digital distance relay for SSSC‐based double‐circuit transmission line using phasor measurement uniten_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dhenuvakonda_Adaptive_2019.pdf
Size:
838.54 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: