Two-phase flow in a horizontal t-junction : pressure drop and phase separation

dc.contributor.authorBertani, C.
dc.contributor.authorMalandrone, M.
dc.contributor.authorPanella, B.
dc.date.accessioned2014-07-18T09:02:33Z
dc.date.available2014-07-18T09:02:33Z
dc.date.issued2007
dc.description.abstractPaper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007.en_US
dc.description.abstractAn experimental investigation of dividing flow rates and pressure drops in a plexiglas tee junction with horizontal inlet, run, and branch sides using air-water mixtures has been performed. The branch stream is orthogonal to the inlet and run streams. The pipes forming the tee junction are about 1 m long, their inner diameter is 10 mm. The flow loop was supplied with compressed air and water through a mixing tee, at 1.5 bar and approximately ambient temperature. Air flow rate ranges from 0.3 to 9 Nl/s, water flow rate from 14.5 to 58 g/s, air superficial velocity from 1.5 to 47 m/s, water superficial velocity from 0.2 to 0.7 m/s and flow quality from 0.6% to 43%. The extraction ratio (branch flow rate / inlet flow rate) ranges from 0 to 1. Intermittent (bubble and slug flow) and annular flow patterns, as well as transition flow patterns have been obtained. Experimental values of flow rate, phases superficial velocity, extraction ratio and pressure drops across the tee junction pipes are here reported. Pressure drop test results across the inlet and branch pipes have also been compared with predicted ones. A new pressure drop correlation have been derived from test data.en_US
dc.description.librariancs2014en_US
dc.format.extent6 pagesen_US
dc.format.mediumPDFen_US
dc.identifier.citationBertani, C, Malandrone, M & Panella, B 2007, 'Two-phase flow in a horizontal t-junction : pressure drop and phase separation', Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007.en_US
dc.identifier.isbn9781868546435
dc.identifier.urihttp://hdl.handle.net/2263/40892
dc.language.isoenen_US
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_US
dc.relation.ispartofHEFAT 2007
dc.rightsUniversity of Pretoriaen_US
dc.rights.uriUniversity of Pretoriaen_US
dc.subjectTwo-phase flow in horizontal t-junctionen_US
dc.subjectPressure drop testen_US
dc.subjectPlexiglas tee junction with horizontal inleten_US
dc.subjectTransition flow patternsen_US
dc.subjectPhases superficial velocityen_US
dc.titleTwo-phase flow in a horizontal t-junction : pressure drop and phase separationen_US
dc.typePresentationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bertani_TwoPhase_2014.pdf
Size:
116.3 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: