Evaluation of the reliability of pulse oximetry, at different attachment sites, to detect hypoxaemia in immobilized impala (Aepyceros melampus)

dc.contributor.authorMtetwa, Thembeka Kim
dc.contributor.authorZeiler, Gareth Edward
dc.contributor.authorLaubscher, Liesel L.
dc.contributor.authorPfitzer, Silke
dc.contributor.authorMeyer, Leith Carl Rodney
dc.contributor.emailthembeka.mtetwa@up.ac.zaen_ZA
dc.date.accessioned2021-01-20T08:42:19Z
dc.date.issued2020-05
dc.description.abstractPlease read abstract in the article.en_ZA
dc.description.departmentCentre for Veterinary Wildlife Studiesen_ZA
dc.description.departmentCompanion Animal Clinical Studiesen_ZA
dc.description.departmentParaclinical Sciencesen_ZA
dc.description.embargo2021-05-01
dc.description.librarianhj2020en_ZA
dc.description.sponsorshipThe University of Pretoria, Faculty of Veterinary Science, Department of Paraclinical Science, South African Veterinary Association (Wildlife Group) and the National Research Foundation.en_ZA
dc.description.urihttps://www.journals.elsevier.com/veterinary-anaesthesia-and-analgesiaen_ZA
dc.identifier.citationMtetwa, T.K., Zeiler, G.E., Laubscher, L. et al. 2020, 'Evaluation of the reliability of pulse oximetry, at different attachment sites, to detect hypoxaemia in immobilized impala (Aepyceros melampus)', Veterinary Anaesthesia and Analgesia, vol. 47, no. 3, pp. 323-333.en_ZA
dc.identifier.issn1467-2987 (print)
dc.identifier.issn1467-2995 (online)
dc.identifier.other10.1016/j.vaa.2019.08.051
dc.identifier.urihttp://hdl.handle.net/2263/78067
dc.language.isoenen_ZA
dc.publisherElsevieren_ZA
dc.rights© 2020 Published by Elsevier Ltd on behalf of Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Notice : this is the author’s version of a work that was accepted for publication in Veterinary Anaesthesia and Analgesia. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Veterinary Anaesthesia and Analgesia, vol. 47, no. 3, pp. 323-333 , 2020. doi : 10.1016/j.vaa.2019.08.051.en_ZA
dc.subjectPulse oximetryen_ZA
dc.subjectOxygen saturationen_ZA
dc.subjectImmobilizationen_ZA
dc.subjectImpala (Aepyceros melampus)en_ZA
dc.titleEvaluation of the reliability of pulse oximetry, at different attachment sites, to detect hypoxaemia in immobilized impala (Aepyceros melampus)en_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mtetwa_Evaluation_2020.pdf
Size:
473.85 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: