Effect of thin film truncation thickness on the heat transfer underestimation from an evaporating droplet on a partial wetting surface

dc.contributor.authorMehrizi, A.A.en
dc.contributor.authorWang, H.en
dc.date.accessioned2017-09-19T12:48:13Z
dc.date.available2017-09-19T12:48:13Z
dc.date.issued2017en
dc.descriptionPapers presented at the 13th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Portoroz, Slovenia on 17-19 July 2017 .en
dc.description.abstractThe thin liquid film near the contact line is important for droplet evaporation on a heated surface, however, it remains a challenge for modeling and simulation since it operates from macroscale down to nanoscale. The nanoscale thin film profile has long been unknown; besides in CFD simulations the meshing work for the thin film could be extremely consuming therefore a truncation is needed to disregard the very thin part of the thin film region. The present study is an attempt to simplify the thin film modeling for partially wetting liquids, based on a recent Atomic Force microscope (AFM) experiments that suggested the partially wetting nanoscale thin film are closely following the macroscale profiles. We conduct a theoretical study on an evaporating sessile droplet and evaluate the effect of thin film truncation size on the overall heat transfer. A small spherical droplet with less than 1mm diameter is investigated and the wall superheat is 1 C°. The contact angles are ranged from 5o to 85o. We evaluate the effect of the dimensionless truncation ratio, i.e. the ratio of the truncation size and droplet height on the overall heat transfer underestimation. The results show that the dimensionless truncation ratio has a critical effect on the heat transfer calculation while the contact angle and the droplet size have relatively weaker influences. It is due to the fact that the variation of truncation ratio has much more effect on the size of the neglecting thin film region.en
dc.description.sponsorshipInternational centre for heat and mass transfer.en
dc.description.sponsorshipAmerican society of thermal and fluids engineers.en
dc.format.extent6 pagesen
dc.format.mediumPDFen
dc.identifier.urihttp://hdl.handle.net/2263/62302
dc.language.isoenen
dc.publisherHEFATen
dc.rightsUniversity of Pretoriaen
dc.subjectDropleten
dc.subjectThin filmen
dc.subjectEvaporationen
dc.subjectContact angleen
dc.subjectTruncationen
dc.subjectHeat transferen
dc.titleEffect of thin film truncation thickness on the heat transfer underestimation from an evaporating droplet on a partial wetting surfaceen
dc.typePresentationen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mehrizi_Effect_2017.pdf
Size:
1.76 MB
Format:
Adobe Portable Document Format
Description:
Presentation