A non-intrusive method for estimating motor efficiency using vibration signature analysis

dc.contributor.authorDlamini, Vusumuzi
dc.contributor.authorNaidoo, Robin
dc.contributor.authorManyage, M.
dc.date.accessioned2014-06-04T10:28:21Z
dc.date.available2014-06-04T10:28:21Z
dc.date.issued2013-02
dc.description.abstractAn accurate method of estimating the efficiency of in-service motors is needed in order to determine the performance of installed motors without disrupting the motor driven process. In this paper, the motor efficiency is estimated using a non-intrusive implementation of the compensated slip method. The motor speed is accurately estimated using motor vibration signature analysis. A few other efficiency estimation techniques are implemented and their performance is compared to the proposed method. It was found that the non-intrusive compensated slip method produced relatively accurate results without having an adverse impact on the availability of the motor under test. This method provides an attractive alternative to highly intrusive techniques that offer similar accuracy.en_US
dc.description.librarianhb2014en_US
dc.description.urihttp://www.elsevier.com/locate/ijepesen_US
dc.identifier.citationDlamini, V, Naidoo, R & Manyage, M 2013, 'A non-intrusive method for estimating motor efficiency using vibration signature analysis', International Journal of Electrical Power and Energy Systems, vol. 45, no.1, pp. 384-390.en_US
dc.identifier.issn0142-0615 (print)
dc.identifier.issn1879-3517 (online)
dc.identifier.other10.1016/j.ijepes.2012.09.015
dc.identifier.urihttp://hdl.handle.net/2263/39994
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rights© 2012 Elsevier Ltd. All rights reserved. Notice : this is the author’s version of a work that was accepted for publication in International journal of electrical power & energy systems.Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in International journal of electrical power & energy systems, vol.45, no.1, pp. 394-390, 2013. doi : 10.1016/j.ijepes.2012.09.015.en_US
dc.subjectMotor efficiencyen_US
dc.subjectSpeed estimationen_US
dc.subjectOnline estimationen_US
dc.subjectVibration signature analysisen_US
dc.subjectEnergy efficiencyen_US
dc.titleA non-intrusive method for estimating motor efficiency using vibration signature analysisen_US
dc.typePostprint Articleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Dlamini_Non_2013.pdf
Size:
563.84 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: