dc.description.abstractOBJECTIVE : This report presents data from four studies to examine standard bone-conduction reference equivalent threshold force levels (RETFL), especially at 4 kHz where anomalous air-bone gaps are common. DESIGN : Data were mined from studies that obtained air- and bone-conduction thresholds from normal-hearing and sensorineural hearing loss (SNHL) participants, using commercial audiometers and standard audiometric transducers. STUDY SAMPLE : There were 249 normal-hearing and 188 SNHL participants. RESULTS : (1) Normal-hearing participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (-1.7 to 0.3 dB) and larger air-bone gaps at 4 kHz (10.6 dB). (2) SNHL participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (-0.7 to 1.7 dB) and a larger air-bone gap at 4 kHz (14.1 dB). (3) The 4-kHz air-bone gap grew with air-conduction threshold from 10.1 dB when the air-conduction threshold was 5-10 dB HL to 21.1 dB when the air-conduction threshold was greater than 60 dB. (4) With the 4-kHz RETFL corrected by the average SNHL air-bone gap, the relationship between RETFL and frequency is linear with a slope of - 12 dB per octave. CONCLUSIONS : The 4-kHz air-bone gaps for listeners with SNHL could be avoided by adjusting the 4-kHz RETFL by - 14.1 dB.en_ZA
dc.description.departmentSpeech-Language Pathology and Audiologyen_ZA
dc.description.librarianhb2016en_ZA
dc.description.sponsorshipPortions of this work were supported by grants R41DC05110 and RC3DC010986 from the National Institutes of Deafness and Other Communication Disorders.en_ZA
dc.description.urihttp://www.tandfonline.com/loi/iija20en_ZA
dc.identifier.citationRobert H. Margolis, Robert H. Eikelboom, Chad Johnson, Samantha M. Ginter, De Wet Swanepoel & Brian C. J. Moore (2013) False air-bone gaps at 4 kHz in listeners with normal hearing and sensorineural hearing loss, International Journal of Audiology, 52:8, 526-532, DOI: 10.3109/14992027.2013.792437.en_ZA
dc.identifier.issn1499-2027 (print)
dc.identifier.issn1708-8186 (online)
dc.identifier.other10.3109/14992027.2013.792437
dc.identifier.urihttp://hdl.handle.net/2263/58411
dc.language.isoenen_ZA
dc.publisherTaylor and Francisen_ZA
dc.rights© 2013 British Society of Audiology, International. This is an electronic version of an article published in International Journal of Audiology, vol. 52, no. 8, pp. 526-532, 2013. doi : 10.3109/14992027.2013.792437. International Journal of Audiology is available online at : www.tandfonline.com/loi/iija20.en_ZA
dc.subjectAudiometryen_ZA
dc.subjectAutomated audiometryen_ZA
dc.subjectHearingen_ZA
dc.subjectHearing testen_ZA
dc.subjectAir conductionen_ZA
dc.subjectBone conductionen_ZA
dc.subjectThresholden_ZA
dc.subjectAir-bone gapen_ZA
dc.subjectArtificial mastoiden_ZA
dc.subjectReference equivalent threshold force levels (RETFL)en_ZA
dc.subjectSensorineural hearing loss (SNHL)en_ZA
dc.titleFalse air-bone gaps at 4 kHz in listeners with normal hearing and sensorineural hearing lossen_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Margolis_False_2013.pdf
Size:
441.83 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: