Smartphone hearing screening with integrated quality control and data management

dc.contributor.authorSwanepoel, De Wet
dc.contributor.authorMyburgh, Hermanus Carel
dc.contributor.authorHowe, David M.
dc.contributor.authorMahomed, Faheema
dc.contributor.authorEikelboom, Robert H.
dc.contributor.emaildewet.swanepoel@up.ac.zaen_US
dc.date.accessioned2014-07-15T09:01:01Z
dc.date.available2014-09-01T00:20:07Z
dc.date.issued2014-12
dc.description.abstractOBJECTIVE : To determine if a smartphone application could be used as a calibrated screening audiometer with real-time noise monitoring for school screening using automated test sequences. DESIGN : The investigation comprised three studies. Study 1 evaluated calibration accuracy across four Samsung S5301 smartphones (Android v4.0.4) using commercial Sennheiser HD202 headphones. Study 2 involved referencing smartphone microphone sensitivity to narrowband noise intensity as measured in octave bands by a sound-level meter between 30 and 75 dB SPL (5 dB increments). Study 3 compared screening outcomes of smartphone based and conventional hearing screening. STUDY SAMPLE : Study 2: 15 normal-hearing subjects (age range, 18 – 22 years; all female). Study 3: 162 children (324 ears) aged 5 to 7 years. RESULTS : Smartphone calibration at 20, 30, and 40 dB was within 1 dB of recommended reference equivalent thresholds levels. Microphone calibration for noise monitoring had maximum variability across phones of 0.9, 0.6, and 2.9 dB at 1, 2, and 4 kHz, respectively, from reference intensities (30 to 75 dB SPL). Screening outcomes demonstrated no signifi cant difference between smartphone and conventional audiometry with an overall referral rate of 4.3% and 3.7%, respectively. CONCLUSIONS : The newly developed smartphone application can be accurately calibrated for audiometry with valid real-time noise monitoring, and clinical results are comparable to conventional screening.en_US
dc.description.librarianhb2014en_US
dc.description.urihttp://informahealthcare.com/loi/ijaen_US
dc.identifier.citationSwanepoel, DW, Myburgh, HC, Howe, DM, Mahomed, F & Eikelboom, RH 2014, 'Smartphone hearing screening with integrated quality control and data management', International Journal of Audiology, vol. 53, no. 12, pp. 841-849.en_US
dc.identifier.issn1499-2027 (print)
dc.identifier.issn1708-8186 (online)
dc.identifier.other10.3109/14992027.2014.920965
dc.identifier.urihttp://hdl.handle.net/2263/40749
dc.language.isoenen_US
dc.publisherInforma Healthcareen_US
dc.rights© 2014 British Society of Audiology, International. This is an electronic version of an article published in International Journal of Audiology, vol. 53, no. 12, pp. 841-849, 2014. doi : 10.3109/14992027.2014.920965. International Journal of Audiology is available online at : http://informahealthcare.com/loi/ija.en_US
dc.subjectAmbient noiseen_US
dc.subjectAudiometryen_US
dc.subjectCalibrationen_US
dc.subjectChildhood hearing lossen_US
dc.subjectHearing screeningen_US
dc.subjectPure-tone audiometryen_US
dc.subjectSchool screeningen_US
dc.titleSmartphone hearing screening with integrated quality control and data managementen_US
dc.typePostprint Articleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Swanepoel_Smartphone_2014.pdf
Size:
905.58 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: