dc.description.abstractBACKGROUND : Advances in intra-abdominal pressure (IAP) measurement have enabled better monitoring and physiological manipulation of patients with intra-abdominal hypertension or abdominal compartment syndrome. This study aimed to determine the correlation between transvesical (TV), transgastric (TG) and direct transperitoneal (TP) IAP monitoring at different IAPs in porcine models. OBJECTIVES : To assess the statistical agreement between TV, TG and TP pressure monitoring in a pneumoperitoneum and an intestinal obstruction intra-abdominal hypertension model at different IAPs. METHODS : Fifty-nine pigs were divided into six groups: a control group (Cr; n=5), three pneumoperitoneum groups at pressures of 20 mmHg, 30 mmHg, and 40 mmHg (Pn20, Pn30, Pn40; n=40), and two intestinal-occlusion groups at pressures of 20 mmHg and 30 mmHg (Oc20, Oc30; n=14). IAP was simultaneously measured in each pig using the three methods at different times. The control group did not have any intervention to increase the IAP. Intra-class correlation was used to assess agreement between the methods. RESULTS : At pressures >20 mmHg, all three methods showed good correlation with each other (Pn20=0.87; Pn30=0.96; Pn40=0.88; Oc20=0.69; Oc30=0.86). Correlation between TP and TG (Cr=0.0; Pn20=0.85; Pn30=0.94; Pn40=0.90; Oc20=0.78; Oc30=0.78); TP and TV (Cr=0.0; Pn20=0.83; Pn30=0.95; Pn40=0.86; Oc20=0.59; Oc30=0.88); and importantly between TV and TG (Cr=0.0; Pn20=0.95; Pn30=0.98; Pn40=0.88; Oc20=0.69; Oc30=0.91) was good. CONCLUSION : All three measurement methods showed good correlation at pressures >20 mmHg and were unaffected by the type of IAP model. These results suggest that either transvesical or transgastric pressure measurements can be used for IAP measurement when TP pressures are >20 mmHg.en_ZA
dc.description.departmentStatisticsen_ZA
dc.description.librarianam2018en_ZA
dc.description.sponsorshipGrant from Extremadura Regional Government through the Plan Regional de Investigación de Extremadura (PRI09A161 to Minimally Invasive Surgery Center Jesús Usón).en_ZA
dc.description.urihttp://www.sajcc.org.zaen_ZA
dc.identifier.citationWise, R.D., Rodseth, R.N., Correa-Martin, L. et al. 2017, 'Correlation between different methods of intra-abdominal pressure monitoring in varying intra-abdominal hypertension models', Southern African Journal of Critical Care, vol. 33, no. 1, pp. 15-18.en_ZA
dc.identifier.issn1562-8264 (print)
dc.identifier.issn2078-676X (online)
dc.identifier.other10.7196/SAJCC.2017.v33i1.327
dc.identifier.urihttp://hdl.handle.net/2263/64017
dc.language.isoenen_ZA
dc.publisherHealth and Medical Publishing Groupen_ZA
dc.rights© 2017 Health and Medical Publishing Group. This article is licensed under a Creative Commons Attribution-NonCommercial Works License (CC BY-NC 3.0) .en_ZA
dc.subjectPatientsen_ZA
dc.subjectIntra-abdominal hypertensionen_ZA
dc.subjectIntra-abdominal pressure (IAP)en_ZA
dc.subjectAbdominal compartment syndromeen_ZA
dc.subjectTransvesical (TV)en_ZA
dc.subjectTransgastric (TG)en_ZA
dc.subjectTransperitoneal (TP)en_ZA
dc.titleCorrelation between different methods of intra-abdominal pressure monitoring in varying intra-abdominal hypertension modelsen_ZA
dc.typeArticleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Wise_Correlation_2017.pdf
Size:
210.23 KB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: