Clinical validation of loop-mediated isothermal amplification for the detection of Escherichia coli sequence type complex 131

dc.contributor.authorPeirano, G.
dc.contributor.authorCastellanos, L. Ricardo
dc.contributor.authorMatsumura, Yasufumi
dc.contributor.authorChaffee, Ryan
dc.contributor.authorCastaneda-Mogollon, Daniel
dc.contributor.authorPillai, Dylan R.
dc.contributor.authorPitout, Johann D.D.
dc.date.accessioned2024-04-16T12:09:34Z
dc.date.issued2024-03
dc.description.abstractThe dissemination of Escherichia coli multidrug-resistant (MDR) STc131 is related to its persistence in the human gastrointestinal tract as efficient gut colonizers. Infection and prevention measures are the cornerstones for preventing STc131 spread. Oral decolonization therapies that target ST131 are being developed. There are no rapid methods available to identify STc131 in human specimens. A loop-mediated isothermal amplification (LAMP) assay (named LAMP-ST131) was developed for the detection of STc131 on well-characterized E. coli isolates and then compared to culture and PCR for urines and stool swabs. With E. coli isolates (n = 720), LAMP-ST131 had a sensitivity (sens) of 100% [95% confidence interval (C.I.) = 98.1–100%)] and a specificity (spec) of 98.9% (95% C.I. = 97.5–99.5%). On urines (n = 550), LAMP-ST131 had a sens of 97.6% (95% C.I. = 89.68–94.33%) and a spec of 92.3% (95% C.I. = 87.68–99.88%), while on stool swabs (n = 278), LAMP-ST131 had a sens of 100% (95% C.I. = 88.7–100%) and a spec of 83.9% (95% C.I. = 78.8–87.9%). LAMP-ST131 detected 10 (urines) and 100 (stool swabs) gene copies/μL. LAMP-ST131 accurately identified STc131 within E. coli isolates and human specimens. The implementation of LAMP-ST131 will aid genomic surveys, enable the rapid implementation of effective infection prevention measures, and identify patients suitable for ST131 decolonization therapies. Such approaches will curb the spread of STc131 and decrease incidence rates of global MDR E. coli infections.en_US
dc.description.departmentMedical Microbiologyen_US
dc.description.embargo2025-08-22
dc.description.librarianhj2024en_US
dc.description.sdgSDG-03:Good heatlh and well-beingen_US
dc.description.sponsorshipThe JPIAMR/Canadian Institute Health Research program, National Institute of Health and ARPHILAKE (JPIAMR/Canadian Institute Health Research program).en_US
dc.description.urihttps://journals.asm.org/journal/jcmen_US
dc.identifier.citationPeirano, G., Castellanos, L.R., Matsumura, Y., Chaffee, R., Castañeda-Mogollón, D., Pillai, D.R. & Pitout, J.D.D. 2024. Clinical validation of loop-mediated isothermal amplification for the detection of Escherichia coli sequence type complex 131. Journal of Clinical Microbiology 62: e01687-23. https://doi.org/10.1128/jcm.01687-23.en_US
dc.identifier.issn1098-660X (online)
dc.identifier.other10.1128/jcm.01687-23
dc.identifier.urihttp://hdl.handle.net/2263/95594
dc.language.isoenen_US
dc.publisherAmerican Society for Microbiologyen_US
dc.rights© 2024 American Society for Microbiology. All Rights Reserved.en_US
dc.subjectEscherichia colien_US
dc.subjectMultidrug-resistant (MDR)en_US
dc.subjectLoop-mediated isothermal amplification (LAMP)en_US
dc.subjectEscherichia coli ST131en_US
dc.subjectSpecimensen_US
dc.subjectSDG-03: Good health and well-beingen_US
dc.titleClinical validation of loop-mediated isothermal amplification for the detection of Escherichia coli sequence type complex 131en_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Peirano_Clinical_2024.pdf
Size:
295.81 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article
Loading...
Thumbnail Image
Name:
Peirano_ClinicalSuppl_2024.pdf
Size:
165.11 KB
Format:
Adobe Portable Document Format
Description:
Supplementary Material

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: