Heat transfer enhancement between vertical wall and air in presence of expired or aspired jets : comparison between free and mixed convection conditions

dc.contributor.authorBartoli, Carlo
dc.date.accessioned2014-12-03T08:39:08Z
dc.date.available2014-12-03T08:39:08Z
dc.date.issued2007
dc.description.abstractPaper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007.en_US
dc.description.abstractThis keynote lecture aims to determine the heat transfer enhancement in natural and in mixed convection between a vertical wall, heated by Joule effect, and air in the presence of small air pulsating aspirated and expired jets, in conditions of medium and large temperature differences between wall and air, namely from 25 to 70K. Experimental measurements have been taken both with and without pulsating and continuous expired and aspirated jets. The expired jets blow out perpendicularly from the wall surface. A thermo camera was used to ensure the wall temperature uniformity. A hot wire anemometer and visualization with smoke were used to found information about the air velocity field. The parameters which maximize the convective heat exchange have been computed. The present research represents a first step of a basic study to optimize the turbine behavior cooled by pulsating jets.en_US
dc.description.librariancs2014en_US
dc.format.extent11 pagesen_US
dc.format.mediumPDFen_US
dc.identifier.citationBartoli, C 2007, Heat transfer enhancement between vertical wall and air in presence of expired or aspired jets: comparison between free and mixed convection conditions, Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007.en_US
dc.identifier.isbn9781868546435
dc.identifier.urihttp://hdl.handle.net/2263/42764
dc.language.isoenen_US
dc.publisherInternational Conference on Heat Transfer, Fluid Mechanics and Thermodynamicsen_US
dc.relation.ispartofHEFAT 2007
dc.rightsUniversity of Pretoriaen_US
dc.rights.uriUniversity of Pretoriaen_US
dc.subjectHeat transfer in natural and in mixed convectionen_US
dc.subjectAspirated and expired jetsen_US
dc.subjectTurbine behavior cooled by pulsating jetsen_US
dc.titleHeat transfer enhancement between vertical wall and air in presence of expired or aspired jets : comparison between free and mixed convection conditionsen_US
dc.typePresentationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bartoli_Heat_2014.pdf
Size:
900.72 KB
Format:
Adobe Portable Document Format
Description:
Presentation

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: