Dynamic response of biofilm to pipe surface and fluid velocity

Loading...
Thumbnail Image

Date

Authors

Cloete, T.E. (Thomas Eugene), 1958-
Westaard, D.
Van Vuuren, S.J.

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Biofouling in pipelines is a function of the inner roughness of the specific piping material that is used in distribution systems and the concomitant biofilm formation. To test the effect of velocity on the growth of biofilm, a Roto-Scope was designed and built to imitate different materials and flow conditions in potable water distribution systems. Biofilm formation was monitored using DAPI staining and the total number of viable bacteria. Increased velocity in the system resulted in a specific detaching velocity, where the formation of biofilm was limited. Most of the time these detaching velocities were not the highest velocities tested. The range of detaching velocities was between ±3 m.s–1 and 4 m.s–1. A flow velocity within this range would thus be ideal for achieving reduced biofilm growth in a distribution system.

Description

Keywords

Fluid velocity, Potable water, Biofouling, Pipe surface, Piping systems

Sustainable Development Goals

Citation

Cloete, TE Westaard, D & Van Vuuren, SJ 2003, 'Dynamic response of biofilm to pipe surface and fluid velocity', Water Science and Technology, vol. 47, no. 5, pp. 57-59. [http://www.sciencedirect.com/science/journal/02731223]