Institutional tuberculosis transmission : controlled trial of upper room ultraviolet air disinfection : a basis for new dosing guidelines

dc.contributor.authorMphaphlele, Matsie
dc.contributor.authorDharmadhikari, Ashwin S.
dc.contributor.authorJensen, Paul A.
dc.contributor.authorRudnick, Stephen N.
dc.contributor.authorVan Reenen, Tobias H.
dc.contributor.authorPagano, Marcello A.
dc.contributor.authorLeuschner, Friedrich Wilhelm
dc.contributor.authorSears, Tim A.
dc.contributor.authorMilonova, Sonya P.
dc.contributor.authorVan der Walt, M.
dc.contributor.authorStoltz, Anton Carel
dc.contributor.authorWeyer, Karin
dc.contributor.authorNardell, Edward Anthony
dc.date.accessioned2015-11-04T08:56:57Z
dc.date.issued2015-08
dc.description.abstractRATIONALE : Transmission is driving the global tuberculosis epidemic, especially in congregate settings. Worldwide, natural ventilation is the most common means of air disinfection, but it is inherently unreliable and of limited use in cold climates. Upper room germicidal ultraviolet (UV) air disinfection with air mixing has been shown to be highly effective, but improved evidence-based dosing guidelines are needed. OBJECTIVES : To test the efficacy of upper room germicidal air disinfection with air mixing to reduce tuberculosis transmission under real hospital conditions, and to define the application parameters responsible as a basis for proposed new dosing guidelines. METHODS : Over an exposure period of 7 months, 90 guinea pigs breathed only untreated exhaust ward air, and another 90 guinea pigs breathed only air from the same six-bed tuberculosis ward on alternate days when upper room germicidal air disinfection was turned on throughout the ward. MEASUREMENTS AND MAIN RESULTS : The tuberculin skin test conversion rates (.6 mm) of the two chambers were compared. The hazard ratio for guinea pigs in the control chamber converting their skin test to positive was 4.9 (95% confidence interval, 2.8–8.6), with an efficacy of approximately 80%. CONCLUSIONS : Upper room germicidal UV air disinfection with air mixing was highly effective in reducing tuberculosis transmission under hospital conditions. These data support using either a total fixture output (rather than electrical or UV lamp wattage) of 15–20 mW/m3 total room volume, or an average whole-room UV irradiance (fluence rate) of 5–7 mW/cm2, calculated by a lighting computer-assisted design program modified for UV use.en_ZA
dc.description.embargo2016-08-31
dc.description.librarianhb2015en_ZA
dc.description.urihttp://www.atsjournals.org/journal/ajrccmen_ZA
dc.identifier.citationMphaphlele, M, Dharmadhikari, AS, Jensen, PA, Rudnick, SN, Van Reenen, TH, Pagano, MA, Leuschner, W, Sears,TA, Milonova, SP, Van Der Walt, M, Stoltz, AC, Weyer, K & Nardell, EA 2015, 'Institutional tuberculosis transmission : controlled trial of upper room ultraviolet air disinfection : a basis for new dosing guidelines', American Journal of Respiratory and Critical Care Medicine, vol. 192, no. 4, pp. 477-484.en_ZA
dc.identifier.issn1073-449X (print)
dc.identifier.issn1535-4970 (online)
dc.identifier.other10.1164/rccm.201501-0060OC
dc.identifier.urihttp://hdl.handle.net/2263/50330
dc.language.isoenen_ZA
dc.publisherAmerican Thoracic Societyen_ZA
dc.rights© 2015 American Thoracic Societyen_ZA
dc.subjectTuberculosis transmissionen_ZA
dc.subjectInfection controlen_ZA
dc.subjectAir disinfectionen_ZA
dc.subjectUltraviolet irradiationen_ZA
dc.subjectTuberculosis preventionen_ZA
dc.subjectTuberculosis (TB)en_ZA
dc.titleInstitutional tuberculosis transmission : controlled trial of upper room ultraviolet air disinfection : a basis for new dosing guidelinesen_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mphaphlele_Institutional_2015.pdf
Size:
1.18 MB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: