Heat transfer and pressure drop in annuli with approximately uniform internal wall temperatures in the transitional flow regime

dc.contributor.authorNdenguma, Dickson Daniel
dc.contributor.authorDirker, Jaco
dc.contributor.authorMeyer, Josua P.
dc.contributor.emailjaco.dirker@up.ac.zaen_ZA
dc.date.accessioned2017-08-01T05:21:08Z
dc.date.issued2017-08
dc.description.abstractAn experimental study was conducted to determine the lower and upper Reynolds number limits of the transitional flow regime, and the characteristics of the heat transfer coefficients and friction factors for annular passages with different hydraulic diameters and diameter ratios in the transitional flow regime. Water was used in this investigation during isothermal, heating and cooling cases. Four horizontal concentric counter-flow tube-in-tube heat exchangers with conventional inlet geometries were considered to obtain the required data. The flow was both hydrodynamic and thermally developing, and the transitional flow was composed of mixed and forced convection types. The wall temperature on the inner surface of the annular passages was approximately uniform, while the outer surface was isothermal. Average Nusselt numbers were obtained for both the heating and cooling cases, while friction factors were obtained for heating, cooling and isothermal adiabatic conditions. Isothermal adiabatic condition was considered for reference purposes. The geometric size of the annular passage and direction of the heat flux (heating and cooling cases of annular fluid) had a significant influence on the heat transfer coefficients, friction factors and Reynolds number span of the transitional flow regime. The annular geometric parameters that represent the geometric size of the annular passage were proposed and found to describe the heat transfer coefficient and friction factors well. Subsequently, correlations for predicting the Nusselt numbers and friction factors in the transitional flow regime were developed.en_ZA
dc.description.departmentMechanical and Aeronautical Engineeringen_ZA
dc.description.embargo2018-08-30
dc.description.librarianhj2017en_ZA
dc.description.urihttp://www.elsevier.com/locate/ijhmten_ZA
dc.identifier.citationNdenguma, D.D., Dirker, J. & Meyer, J.P. 2017, 'Heat transfer and pressure drop in annuli with approximately uniform internal wall temperatures in the transitional flow regime', International Journal of Heat and Mass Transfer, vol. 111, pp. 429-441.en_ZA
dc.identifier.issn1879-2189 (online)
dc.identifier.issn0017-9310 (print)
dc.identifier.other10.1016/j.ij.heatmasstransfer.2017.02.064
dc.identifier.urihttp://hdl.handle.net/2263/61534
dc.language.isoenen_ZA
dc.publisherElsevieren_ZA
dc.rights© 2017 Elsevier Ltd. All rights reserved. Notice : this is the author’s version of a work that was accepted for publication in International Journal of Heat and Mass Transfer. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in International Journal of Heat and Mass Transfer, vol. 111, pp. 429-441, 2017. doi : 10.1016/j.ijheatmasstransfer.2017.02.064.en_ZA
dc.subjectAnnulus diameter ratioen_ZA
dc.subjectHydraulic diameteren_ZA
dc.subjectTransitional flowen_ZA
dc.subjectMixed convectionen_ZA
dc.subjectNusselt numberen_ZA
dc.subjectFriction factoren_ZA
dc.subject.otherEngineering, built environment and information technology articles SDG-07
dc.subject.otherSDG-07: Affordable and clean energy
dc.subject.otherEngineering, built environment and information technology articles SDG-09
dc.subject.otherSDG-09: Industry, innovation and infrastructure
dc.subject.otherEngineering, built environment and information technology articles SDG-12
dc.subject.otherSDG-12: Responsible consumption and production
dc.titleHeat transfer and pressure drop in annuli with approximately uniform internal wall temperatures in the transitional flow regimeen_ZA
dc.typePostprint Articleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ndenguma_Heat_2017.pdf
Size:
725.37 KB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: