Evaluation of the accuracy of visual glucose estimates by healthcare providers and patients at Kalafong Hospital, City of Tshwane, South Africa

dc.contributor.authorMhishi, Simbarashe B.
dc.contributor.authorVan Zyl, Danie G.
dc.date.accessioned2020-11-09T11:43:02Z
dc.date.available2020-11-09T11:43:02Z
dc.date.issued2020
dc.description.abstractBACKGROUND : A patient-centred approach with self-monitoring of blood glucose (SMBG) has emerged as the preferred approach in monitoring and managing blood glucose. The success of SMBG in diabetes treatment and management relies heavily on the accurate and reproducible measurement of blood glucose values. AIM : To evaluate whether patients and healthcare professionals can accurately estimate blood glucose using photometric strips, by visually matching them to colorimetric charts. METHODS : A cross-sectional study design was used with participants enrolled from patients and healthcare providers attending and working at the Diabetes Clinic of Kalafong Provincial Tertiary Hospital (KPTH). A convenience sample of 144 patients and 10 healthcare professionals was enrolled. RESULTS : Limits of agreement of patient and healthcare professional visual estimates were 11.1 to 10.4 mmol/l and 6.7 to 5.7 mmol/l, respectively. The mean difference for estimates by healthcare professionals was 0.8 mmol/l (95% CI 1.30–0.31 mmol/ l) while patient estimates had a mean difference of 0.4 mmol/l (95% CI 1.2−0.5 mmol/l). CONCLUSIONS : The study noted that visual colour matching was inexact and generally would overestimate blood glucose. Healthcare professionals gave visual estimates that were more accurate in comparison with patients.en_ZA
dc.description.departmentInternal Medicineen_ZA
dc.description.librarianam2020en_ZA
dc.description.urihttp://www.jemdsa.co.zaindex.php/JEMDSAen_ZA
dc.identifier.citationMhishi, S.B. & Van Zyl, D.G. 2020, 'Evaluation of the accuracy of visual glucose estimates by healthcare providers and patients at Kalafong Hospital, City of Tshwane, South Africa', Journal of Endocrinology, Metabolism and Diabetes of South Africa, vol. 25, no. 1, pp. 18-23.en_ZA
dc.identifier.issn1608-9677 (print)
dc.identifier.issn2220-1009 (online)
dc.identifier.other10.1080/16089677.2019.1692478
dc.identifier.urihttp://hdl.handle.net/2263/76937
dc.language.isoenen_ZA
dc.publisherMedPharm Publicationsen_ZA
dc.rights© 2019 The Author(s). Open Access article distributed under the terms of the Creative Commons License [CC BY-NC 4.0].en_ZA
dc.subjectColorimetric chartsen_ZA
dc.subjectGlucometeren_ZA
dc.subjectPhotometric stripsen_ZA
dc.subjectVisual estimatesen_ZA
dc.subjectSelf-monitoring of blood glucose (SMBG)en_ZA
dc.titleEvaluation of the accuracy of visual glucose estimates by healthcare providers and patients at Kalafong Hospital, City of Tshwane, South Africaen_ZA
dc.typeArticleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mhishia_Evaluation_2020.pdf
Size:
399.4 KB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: