dc.description.abstractOBJECTIVES : To evaluate the agreement between high-definition oscillometry (HDO) used on the metatarsus or tail base with invasive arterial blood pressures measured in the dorsal pedal artery in anaesthetised cheetahs. STUDY DESIGN : Prospective clinical study. ANIMALS : A group of 13 captive adult cheetahs. METHODS : Cheetahs were immobilised with medetomidine (32–45 μg kg–1) and tiletamine/zolazepam (0.93–1.39 mg kg–1) administered intramuscularly, and anaesthesia was maintained with either isoflurane in oxygen or continuous propofol infusion. Invasive blood pressure was measured via a 20 gauge intra-arterial catheter in the dorsal pedal artery in the metatarsus and used as a reference method for pressures simultaneously estimated using HDO on the contralateral metatarsus and tail base. Bland–Altman plots (for repeated measurements) and criteria defined by the American College of Veterinary Internal Medicine (ACVIM) were used to compare agreement according to the anatomical location of the cuff, the anaesthetic maintenance agent and magnitude of the blood pressure. RESULTS : A total of 147 paired measurements were obtained with HDO on the metatarsus and 135 on the tail. Agreement with invasive pressures was better when HDO was used on the tail (rather than on the metatarsus) with all ACVIM criteria being met. Mean bias (a positive bias meaning that HDO overestimated the invasively measured pressures) ± standard deviation of differences for systolic, diastolic and mean arterial pressures were –7.0 ± 13.9, 4.2 ±12.1 and 4.6 ±11.2 mmHg, respectively, for HDO on the tail, and –11.9 ±15.1, 2.8 ±16.5 and 2.1 ±13.2 mmHg, respectively, for HDO on the metatarsus. Agreement was better during isoflurane anaesthesia than propofol, and at lower blood pressures than at higher. CONCLUSIONS AND CLINICAL RELEVANCE : When used on the tail base of anaesthetised cheetahs, HDO met the ACVIM validation criteria for a noninvasive device, as compared to invasively measured pressures in the dorsal pedal artery.en_US
dc.description.departmentParaclinical Sciencesen_US
dc.description.embargo2023-02-26
dc.description.librarianhj2023en_US
dc.description.urihttps://www.journals.elsevier.com/veterinary-anaesthesia-and-analgesiaen_US
dc.identifier.citationSant Cassia, E.V. & Tordiffe, A.S.W. 2023, 'Agreement of high-definition oscillometry at two cuff locations with invasively measured arterial blood pressures in anaesthetised cheetahs', Veterinary Anaesthesia and Analgesia, vol. 50, no. 2, pp. 170-179, doi : 10.1016/j.vaa.2022.11.009.en_US
dc.identifier.issn1467-2987 (print)
dc.identifier.issn1467-2995 (online)
dc.identifier.other10.1016/j.vaa.2022.11.009
dc.identifier.urihttp://hdl.handle.net/2263/91221
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rights© 2022 Published by Elsevier Ltd on behalf of Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Notice : this is the author’s version of a work that was accepted for publication in Veterinary Anaesthesia and Analgesia. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Veterinary Anaesthesia and Analgesia, vol. 50, no. 2, pp. 170-179, doi : 10.1016/j.vaa.2022.11.009.en_US
dc.subjectHigh-definition oscillometry (HDO)en_US
dc.subjectCheetah (Acinonyx jubatus)en_US
dc.subjectAnaesthesiaen_US
dc.subjectBlood pressureen_US
dc.subjectFeliden_US
dc.subjectOscillometryen_US
dc.subjectSDG-03: Good health and well-beingen_US
dc.titleAgreement of high-definition oscillometry at two cuff locations with invasively measured arterial blood pressures in anaesthetised cheetahsen_US
dc.typePostprint Articleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SantCassia_Agreement_2023.pdf
Size:
1.31 MB
Format:
Adobe Portable Document Format
Description:
Postprint Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: