Review of pump suction reducer selection : eccentric or concentric reducers

dc.contributor.authorMahaffey, Ross M.
dc.contributor.authorVan Vuuren, S.J.
dc.contributor.emailfanie.vanvuuren@up.ac.zaen_ZA
dc.date.accessioned2015-05-28T11:09:59Z
dc.date.available2015-05-28T11:09:59Z
dc.date.issued2014-10
dc.description.abstractEccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity distribution at the inlet to the pump. It was found that eccentric reducers with angles greater or equal to 15° and concentric reducers with an angle greater or equal to 20° did not pass the assessment criteria related to the inlet conditions. Air could be hydraulically transported through all of the concentric reducers modelled except for the 20° concentric reducer. A correctly designed concentric reducer will not only provide a more uniform velocity distribution in comparison to an eccentric reducer, but will allow for the hydraulic transportation of air through the reducer.en_ZA
dc.description.librarianam2015en_ZA
dc.description.urihttp://www.journals.co.za/ej/ejour_civileng.htmlen_ZA
dc.identifier.citationMahaffey, RM & Van Vuuren, SJ 2014, 'Review of pump suction reducer selection : eccentric or concentric reducers', Journal of the South African Institution of Civil Engineering, vol. 56, no. 3, pp. 65-76en_ZA
dc.identifier.issn1021-2019
dc.identifier.urihttp://hdl.handle.net/2263/45327
dc.language.isoenen_ZA
dc.publisherSouth African Institution of Civil Engineeringen_ZA
dc.rightsSouth African Institution of Civil Engineeringen_ZA
dc.subjectPump station designen_ZA
dc.subjectEccentric and concentric reducersen_ZA
dc.subjectComputational fluid dynamics (CFD)en_ZA
dc.subjectNumerical modellingen_ZA
dc.subjectAir transport in pipelinesen_ZA
dc.titleReview of pump suction reducer selection : eccentric or concentric reducersen_ZA
dc.typeArticleen_ZA

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mahaffey_Review_2014.pdf
Size:
990 KB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: