Comparison of pregnancy incidence among African women in a randomized trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) or a levonorgestrel (LNG) implant for contraception

Show simple item record

dc.contributor.author Onono, Maricianah
dc.contributor.author Nanda, Kavita
dc.contributor.author Heller, Kate B.
dc.contributor.author Taylor, Doug
dc.contributor.author Yacobson, Irina
dc.contributor.author Heffron, Renee
dc.contributor.author Kasaro, Margaret Phiri
dc.contributor.author Louw, Cheryl
dc.contributor.author Nhlabasti, Zelda
dc.contributor.author Palanee-Phillips, Thesla
dc.contributor.author Smit, Jenni
dc.contributor.author Wakhungu, Imelda
dc.contributor.author Gichangi, Peter B.
dc.contributor.author Mugo, Nelly R.
dc.contributor.author Morrison, Charles
dc.contributor.author Baeten, Jared M.
dc.date.accessioned 2021-04-01T05:30:32Z
dc.date.available 2021-04-01T05:30:32Z
dc.date.issued 2020
dc.description.abstract OBJECTIVE: The objective was to address bias in contraception efficacy studies through a randomized study trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) and a levonorgestrel (LNG) implant. STUDY DESIGN: We analyzed data from the Evidence for Contraceptive Options and HIV Outcomes Trial, which assessed HIV incidence among 7829 women from 12 sites in eSwatini, Kenya, South Africa and Zambia seeking effective contraception and who consented to be randomized to DMPA-IM, copper IUD or LNG implant. We used Cox proportional hazards regression adjusted for condom use to compare pregnancy incidence during both perfect and typical (i.e., allowing temporary interruptions) use. RESULTS: A total of 7710 women contributed to this analysis. Seventy pregnancies occurred during perfect and 85 during typical use. There was no statistically significant difference in perfect use pregnancy incidence among the methods: 0.61 per 100 woman-years for DMPA-IM [95% confidence interval (CI) 0.36–0.96], 1.06 for copper IUD (95% CI 0.72–1.50) and 0.63 for LNG implants (95% CI 0.39–0.96). Typical use pregnancy rates were also largely similar: 0.87 per 100 woman-years for DMPA-IM (95% CI 0.58–1.25), 1.11 for copper IUD (95% CI 0.77–1.54) and 0.63 for LNG implants (95% CI 0.39–0.96). CONCLUSIONS: In this randomized trial of highly effective contraceptive methods among African women, both perfect and typical use resulted in low pregnancy rates. Our findings provide strong justification for improving access to a broader range of longer-acting contraceptive options including LNG implants and copper IUD for African women. en_ZA
dc.description.department Family Medicine en_ZA
dc.description.librarian pm2021 en_ZA
dc.description.sponsorship The Bill & Melinda Gates Foundation, the United States Agency for International Development, the Swedish International Development Cooperation Agency as part of the EDCTP2 program supported by the European Union, the South African Medical Research Council and the United Nations Population Fund. Contraceptive supplies were donated by the Government of South Africa and United States Agency for International Development. en_ZA
dc.description.uri https://www.journals.elsevier.com/conx en_ZA
dc.identifier.citation Onono, M., Nanda, K., Heller, K.B. et al. 2020, 'Comparison of pregnancy incidence among African women in a randomized trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) or a levonorgestrel (LNG) implant for contraception', Contraception: X, vol. 2, art. 100026, pp. 1-10. en_ZA
dc.identifier.issn 2590-1516
dc.identifier.other 10.1016/j.conx.2020.100026
dc.identifier.uri http://hdl.handle.net/2263/79145
dc.language.iso en en_ZA
dc.publisher Elsevier en_ZA
dc.rights © 2020 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). en_ZA
dc.subject Hormonal contraception en_ZA
dc.subject Injectables en_ZA
dc.subject Implants en_ZA
dc.subject Copper intrauterine device en_ZA
dc.subject Africa en_ZA
dc.subject Pregnancy incidence en_ZA
dc.subject Intramuscular depot medroxyprogesterone acetate (DMPA-IM) en_ZA
dc.subject Intrauterine device (IUD) en_ZA
dc.subject Levonorgestrel (LNG) en_ZA
dc.title Comparison of pregnancy incidence among African women in a randomized trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) or a levonorgestrel (LNG) implant for contraception en_ZA
dc.type Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record