The socket-shield technique at molar sites : a proof-of-principle technique report

Show simple item record

dc.contributor.author Schwimer, Charles W.
dc.contributor.author Gluckman, Howard
dc.contributor.author Salama, Maurice
dc.contributor.author Nagy, Katalin N.
dc.contributor.author Du Toit, Jonathan
dc.date.accessioned 2020-01-13T10:48:15Z
dc.date.issued 2019-02
dc.description.abstract The socket-shield technique for avoiding postextraction tissue alteration was first described in 2010. The technique was developed for hopeless teeth in anterior esthetic sites but has not yet been described for molar sites. Managing postextractive ridge changes in the posterior region by prevention or regeneration remains a challenge. The socket shield aims to offset these ridge changes wherever possible, preserving the patient’s residual tissues at immediate implants. This technique report describes the molar socket-shield step by step. en_ZA
dc.description.department Periodontics and Oral Medicine en_ZA
dc.description.embargo 2020-02-01
dc.description.librarian hj2020 en_ZA
dc.description.uri http://www.journals.elsevier.com/journal-of-prosthetic-dentistry en_ZA
dc.identifier.citation Schwimer, C.W., Gluckman, H., Salama, M. et al. 2019, 'The socket-shield technique at molar sites : a proof-of-principle technique report', The Journal of Prosthetic Dentistry, vol. 121, no. 2, pp. 229-233. en_ZA
dc.identifier.issn 0022-3913 (print)
dc.identifier.issn 1097-6841 (online)
dc.identifier.other 10.1016/j.prosdent.2018.05.006
dc.identifier.uri http://hdl.handle.net/2263/72833
dc.language.iso en en_ZA
dc.publisher Elsevier en_ZA
dc.rights © 2018 by the Editorial Council for The Journal of Prosthetic Dentistry. Notice : this is the author’s version of a work that was accepted for publication in Journal of Prosthetic Dentistry. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Journal of Prosthetic Dentistry, vol. 121, no. 2, pp. 229-233, 2019. doi : 10.1016/j.prosdent.2018.05.006. en_ZA
dc.subject Socket-shield technique en_ZA
dc.subject Alterations post-extraction en_ZA
dc.subject Implant placement en_ZA
dc.subject Aesthetic zone en_ZA
dc.subject Partial extraction therapy en_ZA
dc.subject Buccofacial tooth structure en_ZA
dc.subject Anterior implant site en_ZA
dc.subject Alveolar ridge en_ZA
dc.subject Molar implant placement en_ZA
dc.title The socket-shield technique at molar sites : a proof-of-principle technique report en_ZA
dc.type Postprint Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record