Effect of an intervertebral disk spacer on stiffness after monocortical screw/polymethylmethacrylate fixation in simulated and cadaveric canine cervical vertebral columns

Show simple item record

dc.contributor.author Hettlich, Bianca F.
dc.contributor.author Allen, Matthew J.
dc.contributor.author Glucksman, Gabriela S.
dc.contributor.author Fosgate, Geoffrey Theodore
dc.contributor.author Litsky, Alan S.
dc.date.accessioned 2015-06-30T06:15:30Z
dc.date.available 2015-06-30T06:15:30Z
dc.date.issued 2014-11
dc.description.abstract OBJECTIVE : To determine the biomechanical effect of an intervertebral spacer on construct stiffness in a PVC model and cadaveric canine cervical vertebral columns stabilized with monocortical screws/polymethylmethacrylate (PMMA). STUDY DESIGN : Biomechanical study. SAMPLE POPULATION : PVC pipe; cadaveric canine vertebral columns METHODS : PVC model – PVC pipe was used to create a gap model mimicking vertebral endplate orientation and disk space width of large-breed canine cervical vertebrae; 6 models had a 4-mm gap with no spacer (PVC group 1); 6 had a PVC pipe ring spacer filling the gap (PCV group 2). Animals – large breed cadaveric canine cervical vertebral columns (C2-C7) from skeletally mature dogs without (cadaveric group 1, n=6, historical data) and with an intervertebral disk spacer (cadaveric group 2, n=6) were used. All PVC models and cadaver specimens were instrumented with monocortical titanium screws/PMMA. Stiffness of the 2 PVC groups was compared in extension, flexion, and lateral bending using non-destructive 4- point bend testing. Stiffness testing in all 3 directions was performed of the unaltered C4-C5 vertebral motion unit in cadaveric spines and repeated after placement of an intervertebral cortical allograft ring and instrumentation. Data were compared using a linear mixed model approach that also incorporated data from previously tested spines with the same screw/PMMA construct but without disk spacer (cadaveric group 1). RESULTS : Addition of a spacer increased construct stiffness in both the PVC model (P< .001) and cadaveric vertebral columns (P<.001) compared to fixation without a spacer. CONCLUSIONS : Addition of an intervertebral spacer significantly increased construct stiffness of monocortical screw/PMMA fixation. en_ZA
dc.description.embargo 2015-11-30 en_ZA
dc.description.librarian hb2015 en_ZA
dc.description.sponsorship Canine Intramural Fund, College of Veterinary Medicine, The Ohio State University. en_ZA
dc.description.uri http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-950X en_ZA
dc.identifier.citation Hettlich, BF, Allen, MJ, Glucksman, GS, Fosgate, GT & Litsky, AS 2014, 'Effect of an intervertebral disk spacer on stiffness after monocortical screw / polymethylmethacrylate fixation in simulated and cadaveric canine cervical vertebral columns', Veterinary Surgery, vol. 43, no. 8, pp. 988-994. en_ZA
dc.identifier.issn 0161-3499 (print)
dc.identifier.issn 1532-950X (online)
dc.identifier.other 10.1111/j.1532-950X.2014.12165.x
dc.identifier.uri http://hdl.handle.net/2263/45811
dc.language.iso en en_ZA
dc.publisher Wiley en_ZA
dc.relation.requires Adobe Acrobat Reader en
dc.rights © 2014 by The American College of Veterinary Surgeons. This is the pre-peer reviewed version of the following article : Effect of an Intervertebral Disk Spacer on Stiffness After Monocortical Screw/Polymethylmethacrylate Fixation in Simulated and Cadaveric Canine Cervical Vertebral Columns, Veterinary Surgery, vol. 43, no. 8, pp. 988-994. 2014, doi :10.1111/j.1532-950X.2014.12165.x. The definite version is available at : http://onlinelibrary.wiley.comjournal/10.1111/(ISSN)1532-950X en_ZA
dc.subject Intervertebral disk spacer en_ZA
dc.subject Stiffness en_ZA
dc.subject Biomechanical effect en_ZA
dc.subject Cadaveric canine cervical vertebral columns en_ZA
dc.subject Monocortical screws en_ZA
dc.subject Polymethylmethacrylate (PMMA) en_ZA
dc.title Effect of an intervertebral disk spacer on stiffness after monocortical screw/polymethylmethacrylate fixation in simulated and cadaveric canine cervical vertebral columns en_ZA
dc.type Postprint Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record