Conceptual global optimal bounds for COP of Cascaded-Flashed R134a irreversible refrigeration system

Please be advised that the site will be down for maintenance on Sunday, September 1, 2024, from 08:00 to 18:00, and again on Monday, September 2, 2024, from 08:00 to 09:00. We apologize for any inconvenience this may cause.

Show simple item record

dc.contributor.author Abdel-Rahim, Yousef M.
dc.contributor.author Rahman, Muhammad M.
dc.date.accessioned 2015-04-24T06:32:20Z
dc.date.available 2015-04-24T06:32:20Z
dc.date.issued 2014
dc.description.abstract Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.description.abstract Present study of the flash-mixed two-stage cascade R134a refrigeration system has considered the optimal COP cycle characteristics over whole ranges of all cycle controlling parameters, with consideration of pressure and thermal losses in all units and connecting lines of cycle. Application of Monte Carlo Method (MCM) has proved to be quite effective in optimizing cycle performance. COP, cooling power Qin, total input power Wt and second law efficiency ŋII are used as cycle performance parameters. Present COP and ŋII results have been shown to compare well with other published results. COP hyperbolically decreases with Wt. Higher COP values at lower Wt values exemplify the favorable use of this cycle in small-scale units. The study shows a parabolic relationship between COP and Qin. Higher COP values at higher loads favor the use of this cycle for cooling purposes. Values of COP increase with ηII, justifying that reductions in cycle irreversibilities result in enhancement of COP. Systems having intermediate pressures that are about equal to geometric mean of terminal pressures as well as systems with about equal mass flow rates in upper and lower cycles result in optimum values of COP. This concludes that better systems have their units of comparable sizes. MCM analysis shows that both evaporative temperature t8 and inlet superheated temperatures to LP compressor tsup have monotonic effects on conceptual optimal upper-enveloped COP bounds, with their optimum normalized values are both in the range 0.4 to 0.8 of their variation ranges of 265-284.4°K, 265.5-293.9°K respectively. COP is not sensitive to the cycle highest temperature T4 as long as it is below about 332.5°K, beyond which COP suffers very sharp decrease. This is in favor of using reasonable pressure ratio of HP compressor. Fitted equations are developed to relate upper bounds of COP with these three temperatures. en_ZA
dc.description.librarian dc2015 en_ZA
dc.format.extent 9 pages en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation Abdel-Rahim, YM & Rahman, MM 2014, 'Conceptual global optimal bounds for COP of Cascaded-Flashed R134a irreversible refrigeration system', Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.identifier.isbn 97817759206873
dc.identifier.uri http://hdl.handle.net/2263/44692
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.rights © 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en_ZA
dc.subject Flash-mixed two-stage cascade en_ZA
dc.subject R134a refrigeration system en_ZA
dc.subject COP cycle characteristics en_ZA
dc.subject COP en_ZA
dc.subject Monte Carlo Method en_ZA
dc.subject MCM en_ZA
dc.subject Evaporative temperature en_ZA
dc.title Conceptual global optimal bounds for COP of Cascaded-Flashed R134a irreversible refrigeration system en_ZA
dc.type Presentation en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record