Numerical simulation of GE 7001 EA gas turbine using experimental data for compressor inlet air cooling

Show simple item record

dc.contributor.author Ali, M.
dc.contributor.author Zeitoun, O.
dc.contributor.author Al-Ansary, H.
dc.contributor.author Nuhait, A.
dc.date.accessioned 2015-04-23T12:16:36Z
dc.date.available 2015-04-23T12:16:36Z
dc.date.issued 2014
dc.description.abstract Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.description.abstract In this paper computer Simulation of GE 7001 EA gas turbine that widely used in the kingdom of Saudi Arabia is reported. Simulation is done using cooled air data obtained previously from different experiments. These data are used as input to the compressor to see its effect on the output power and efficiency of the gas turbine. GE 7001EA gas turbine, (GE7121EA models) is simulated using THERMOFLEX software. The specifications of this type of turbines are built in this software. This type of gas turbine model is used in Riyadh and Taif power stations. ISO conditions and actual weather conditions are used for simulations. The results show that the maximum increase in the net power output is about 12, 6 and 5.8% depend on the used cooling data. On the other hand, the maximum percentage increase in efficiency is turned to about 2.5, 1.3 and 0.9 respectively. en_ZA
dc.description.librarian cf2015 en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation Ali, M, Zeitoun, O, Al-Ansary, H, Nuhait, A 2014, 'Numerical simulation of GE 7001 EA gas turbine using experimental data for compressor inlet air cooling', Paper presented to the 10th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Florida, 14-16 July 2014. en_ZA
dc.identifier.isbn 97817759206873
dc.identifier.uri http://hdl.handle.net/2263/44629
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.rights © 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en_ZA
dc.subject Gas turbine en_ZA
dc.subject Compressor inlet air cooling en_ZA
dc.subject Output efficiency en_ZA
dc.subject Output power en_ZA
dc.subject Power stations en_ZA
dc.subject Weather conditions en_ZA
dc.title Numerical simulation of GE 7001 EA gas turbine using experimental data for compressor inlet air cooling en_ZA
dc.type Presentation en_ZA