Design and use of radiant barriers as thermal insulation for high inertia houses in tropical conditions - a case study

Show simple item record

dc.contributor.author Miranville, F.
dc.contributor.author Mara, T.
dc.contributor.author Adélard, L.
dc.contributor.author Sériacaroupin, J.
dc.date.accessioned 2014-12-17T10:31:46Z
dc.date.available 2014-12-17T10:31:46Z
dc.date.issued 2007
dc.description.abstract Paper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007. en_ZA
dc.description.abstract This paper deals with the thermal design and performance of a roof-mounted radiant barrier, installed in a high inertia house in tropical and humid conditions. Using dynamic simulations of a mathematical model of a whole house including a radiant barrier installed between the roof slab and the ceiling, the thermal performance of the roof is calculated and the thermal comfort in the house is evaluated using the psychometric chart. The mean method is more particularly used to assess the thermal resistance of the building roof and lead to a value which can be compared to those obtained using mass insulation product such as polyurethane foam or glass wool. The aim of the study is to evaluate the most appropriate technical solution to insulate high inertia roofs of buildings, which can accumulate much energy during the day and create uncomfortable thermal conditions in the late afternoon and during the night in summer tropical conditions. en_ZA
dc.description.librarian cs2014 en_ZA
dc.format.extent 6 pages en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation Miranville, F, Mara, T, Adélard, L & Sériacaroupin, J 2007, Design and use of radiant barriers as thermal insulation for high inertia houses in tropical conditions - a case study, Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007. en_ZA
dc.identifier.isbn 9781868546435
dc.identifier.uri http://hdl.handle.net/2263/43088
dc.language.iso en en_ZA
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.relation.ispartof HEFAT 2007
dc.rights University of Pretoria en_ZA
dc.rights.uri University of Pretoria en_US
dc.subject Roof-mounted radiant barrier en_ZA
dc.subject Insulate high inertia roofs en_ZA
dc.subject High inertia roofs of buildings en_ZA
dc.subject Summer tropical conditions en_ZA
dc.title Design and use of radiant barriers as thermal insulation for high inertia houses in tropical conditions - a case study en_ZA
dc.type Presentation en_ZA