dc.description.abstract |
Paper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007. |
en_ZA |
dc.description.abstract |
According to the European Waste Directive 2000/76/CE,
temperature of gaseous emissions in the postcombustion zone
of an incinerator is one of the key parameters that has to be
continuously measured and controlled. A bare thermocouple is
generally affected by different physical contributes which make
the gas temperature measurement incorrect.
This paper analyzes the errors that can arise when using a
bare thermocouple, describes principle design and uncertainty
of a suction pyrometer and a method to characterize a waste
incinerator. Results allow a correct thermal characterization of
the plant permitting a better energy management. |
en_ZA |
dc.description.librarian |
cs2014 |
en_ZA |
dc.format.extent |
6 pages |
en_ZA |
dc.format.medium |
PDF |
en_ZA |
dc.identifier.citation |
Marchesi, R & Rinaldi F 2007, Thermal characterisation of a solid waste incinerator by temperature measurements with suction pyrometers, Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007. |
en_ZA |
dc.identifier.isbn |
9781868546435 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/43067 |
|
dc.language.iso |
en |
en_ZA |
dc.publisher |
International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics |
en_ZA |
dc.relation.ispartof |
HEFAT 2007 |
|
dc.rights |
University of Pretoria |
en_ZA |
dc.rights.uri |
University of Pretoria |
en_US |
dc.subject |
Gas temperature measurement |
en_ZA |
dc.subject |
Thermocouple |
en_ZA |
dc.subject |
Waste incinerator |
en_ZA |
dc.subject |
Pyrometer |
en_ZA |
dc.subject |
Solid waste incinerator |
en_ZA |
dc.title |
Thermal characterisation of a solid waste incinerator by temperature measurements with suction pyrometers |
en_ZA |
dc.type |
Presentation |
en_ZA |