Preliminary assessment of the fluid-structure interaction effects in a GEN IV LMR

Show simple item record

dc.contributor.author Lo Frano, R.
dc.contributor.author Forasassi, G.
dc.date.accessioned 2014-12-15T07:42:17Z
dc.date.available 2014-12-15T07:42:17Z
dc.date.issued 2012
dc.description.abstract Paper presented at the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012. en_ZA
dc.description.abstract The devastating Fukushima 2011 earthquake and tsunami and their consequent multi-reactor damages in Japan, mainly due to the hydrodynamic effects arisen from the fluid-structure interaction, had a significant impact on the global nuclear energy industry. These events highlighted the need to design the future/existing nuclear installations in order to be able to assure a huge safety level in reference accident configuration and, also, in beyond design conditions. In this framework it is extremely important to analyze the lessons learnt from the Fukushima events and to evaluate the safety margins of the nuclear power plants in particular, under ongoing unexpected severe earthquake, such as a beyond design basis one (BDBE). The aim of this paper deals with the evaluation of the dynamic effects seismically induced by the fluid-structure interaction in an under development Gen IV Liquid Metal Reactor (LMR), specifically with reference to the European reactor configuration. The fluid-structure interaction and sloshing phenomena were numerically analyzed taking into account the non linearities and instabilities due to the influence of material and geometrical parameters. In order to attain the mentioned goal a suitable numerical procedure based on an external coupling between dynamic and structural codes (as MSC.Dytran and MARC) was applied, setting up a detailed 3-D FEM model as well as implementing a specific algorithm capable to analyze the coupling effects between the considered fluid and the structures and the sloshing phenomenon. Numerical results were presented and discussed highlighting the importance of the fluid-structure interaction effects in terms of stress intensity as well as the capacity of internals and vessel walls to withstand wave’s impacts. en_ZA
dc.description.librarian dc2014 en_ZA
dc.format.extent 8 pages en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation Lo Frano, R & Forasassi, G 2012, Preliminary assessment of the fluid-structure interaction effects in a GEN IV LMR, Paper presented to the 9th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Malta, 16-18 July, 2012. en_ZA
dc.identifier.isbn 9781868549863
dc.identifier.uri http://hdl.handle.net/2263/43014
dc.language.iso en en_ZA
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.relation.ispartof HEFAT 2012 en_US
dc.rights University of Pretoria en_ZA
dc.subject Fukushima 2011 earthquake en_ZA
dc.subject Multi-reactor damages en_ZA
dc.subject Hydrodynamic effects en_ZA
dc.subject Fluid-structure interaction (FSI) en_ZA
dc.subject Beyond design basis one (BDBE) en_ZA
dc.subject Gen IV liquid metal reactor en_ZA
dc.subject MSC.Dytran en_ZA
dc.subject MARC en_ZA
dc.subject 3-D FEM model en_ZA
dc.title Preliminary assessment of the fluid-structure interaction effects in a GEN IV LMR en_ZA
dc.type Presentation en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record