Design and optimization of a downhole coaxial heat exchanger for an enhanced geothermal system (EGS)

Loading...
Thumbnail Image

Date

Authors

Yekoladio, Peni Junior
Bello-Ochende, Tunde
Meyer, Josua P.

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

The present study considers the design, performance analysis and optimization of a downhole coaxial heat exchanger for an enhanced geothermal system (EGS). The optimum mass flow rate of the geothermal fluid for minimum pumping power and maximum extracted heat energy was determined. In addition, the coaxial pipes of the downhole heat exchanger were sized based on the optimum geothermal mass flow rate and steady-state operation. Transient effect or time-dependent cooling of the Earth underground, and the optimum amount and size of perforations at the inner pipe entrance region to regulate the flow of the geothermal fluid were disregarded to simplify the analysis. The paper consists of an analytical and numerical thermodynamic optimization of a downhole coaxial heat exchanger used to extract the maximum possible energy from the Earth’s deep underground (2 km and deeper below the surface) for direct usage, and subject to a nearly linear increase in geothermal gradient with depth. The thermodynamic optimization process and entropy generation minimization (EGM) analysis were performed to minimize heat transfer and fluid friction irreversibilities. An optimum diameter ratio of the coaxial pipes for minimum pressure drop in both limits of the fully turbulent and laminar fullydeveloped flow regime was determined and observed to be nearly the same irrespective of the flow regime. Furthermore, an optimum geothermal mass flow rate and an optimum geometry of the downhole coaxial heat exchanger were determined for maximum net power output. Conducting an energetic and exergetic analysis to evaluate the performance of binary power cycle, higher Earth’s temperature gradient and lower geofluid rejection temperatures were observed to yield maximum firstand second-law efficiencies.

Description

Keywords

Exergy analysis, Downhole coaxial heat exchanger, Binary cycle, Enhanced geothermal system (EGS), Entropy generation minimization (EGM)

Sustainable Development Goals

Citation

Yekoladio, PJ, Bello-Ochende, T & Meyer, JP 2013, 'Design and optimization of a downhole coaxial heat exchanger for an enhanced geothermal system (EGS)', Renewable Energy, vol. 55, no. 7, pp. 128-137.