dc.description.abstract |
Plastic shrinkage cracking occurs when fresh concrete is drying and restrained from deformation, which typically
results in cracking. The tensile stresses causing cracking result from the negative capillary pressure that develops
in the drying concrete. This study developed a model that uses live in-situ capillary pressure measurements in
fresh concrete to control the capillary pressure response to prevent plastic shrinkage cracking at any reasonable
evaporation rate, making it a valuable tool for preventing plastic shrinkage cracking. |
en_US |
dc.description.department |
Civil Engineering |
en_US |
dc.description.librarian |
am2024 |
en_US |
dc.description.sdg |
SDG-09: Industry, innovation and infrastructure |
en_US |
dc.description.uri |
http://www.elsevier.com/locate/conbuildmat |
en_US |
dc.identifier.citation |
Deysel, R.C., Boshoff, W.P., Smit, M.S. 2023, 'Implementing capillary pressure control measures to prevent plastic shrinkage cracking in concrete', Construction and Building Materials, vol. 397, art. 132407, pp. 1-11.
https://DOI.org/10.1016/j.conbuildmat.2023.132407. |
en_US |
dc.identifier.issn |
0950-0618 (print) |
|
dc.identifier.issn |
1879-0526 (online) |
|
dc.identifier.other |
10.1016/j.conbuildmat.2023.132407 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/95936 |
|
dc.language.iso |
en |
en_US |
dc.publisher |
Elsevier |
en_US |
dc.rights |
© 2023 The Authors. This is an open access article under the CC BY-NC license. |
en_US |
dc.subject |
Plastic shrinkage |
en_US |
dc.subject |
Plastic shrinkage cracking |
en_US |
dc.subject |
Fresh concrete |
en_US |
dc.subject |
Tensiometers |
en_US |
dc.subject |
Capillary pressure |
en_US |
dc.subject |
No cracking capillary pressure boundary model |
en_US |
dc.subject |
Empirical model |
en_US |
dc.subject |
SDG-09: Industry, innovation and infrastructure |
en_US |
dc.title |
Implementing capillary pressure control measures to prevent plastic shrinkage cracking in concrete |
en_US |
dc.type |
Article |
en_US |