dc.contributor.author |
Mtetwa, Thembeka Kim
|
|
dc.contributor.author |
Snelling, Edward P.
|
|
dc.contributor.author |
Donaldson, Ashleigh Claire
|
|
dc.contributor.author |
Buss, Peter Erik
|
|
dc.contributor.author |
Meyer, Leith Carl Rodney
|
|
dc.date.accessioned |
2023-10-18T14:30:24Z |
|
dc.date.available |
2023-10-18T14:30:24Z |
|
dc.date.issued |
2023-09 |
|
dc.description.abstract |
CONCLUSIONS: The EPOC cSaO2 is unreliable and should not be used to monitor blood oxygenation in immobilized white rhinoceroses. |
en_US |
dc.description.abstract |
Please read abstract in the article. |
en_US |
dc.description.department |
Anatomy and Physiology |
en_US |
dc.description.department |
Centre for Veterinary Wildlife Studies |
en_US |
dc.description.department |
Paraclinical Sciences |
en_US |
dc.description.department |
Production Animal Studies |
en_US |
dc.description.sponsorship |
Agriculture Sector Education Training Authority; Centre for Veterinary Wildlife Research; Department of Paraclinical Sciences, University of Pretoria; Department of Veterinary Tropical Diseases, University of Pretoria; Dnata Wild-over-Wildlife; South African Government Health and Welfare Sector Education and Training Authority; Wiederhold Foundation. |
en_US |
dc.description.uri |
http://www.wileyonlinelibrary.com/journal/vcp |
en_US |
dc.identifier.citation |
Mtetwa, TK, Snelling, EP, Donaldson, AC, Buss, PE, Meyer, LCR. Reliability of the Enterprise Point-of-Care (EPOC) blood analyzer's calculated arterial oxygen-hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum). Veterinary Clinical Pathology 2023; 52: 417-421. doi:10.1111/vcp.13236. |
en_US |
dc.identifier.issn |
0275-6382 (print) |
|
dc.identifier.issn |
1939-165X (online) |
|
dc.identifier.other |
10.1111/vcp.13236 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/92992 |
|
dc.language.iso |
en |
en_US |
dc.publisher |
Wiley |
en_US |
dc.rights |
© 2023 The Authors. Veterinary Clinical Pathology published by Wiley Periodicals LLC on behalf of the American Society for Veterinary Clinical Pathology. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License. |
en_US |
dc.subject |
Blood gas analysis |
en_US |
dc.subject |
Hypoxemia |
en_US |
dc.subject |
Oxygen saturation |
en_US |
dc.subject |
Wildlife |
en_US |
dc.subject |
Enterprise point-of-care (EPOC) |
en_US |
dc.subject |
White rhinoceros (Ceratotherium simum) |
en_US |
dc.subject |
SDG-03: Good health and well-being |
en_US |
dc.title |
Reliability of the enterprise point-of-care (EPOC) blood analyzer's calculated arterial oxygen-hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum) |
en_US |
dc.type |
Article |
en_US |