Reliability of the enterprise point-of-care (EPOC) blood analyzer's calculated arterial oxygen-hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum)

Show simple item record

dc.contributor.author Mtetwa, Thembeka Kim
dc.contributor.author Snelling, Edward P.
dc.contributor.author Donaldson, Ashleigh Claire
dc.contributor.author Buss, Peter Erik
dc.contributor.author Meyer, Leith Carl Rodney
dc.date.accessioned 2023-10-18T14:30:24Z
dc.date.available 2023-10-18T14:30:24Z
dc.date.issued 2023-09
dc.description.abstract CONCLUSIONS: The EPOC cSaO2 is unreliable and should not be used to monitor blood oxygenation in immobilized white rhinoceroses. en_US
dc.description.abstract Please read abstract in the article. en_US
dc.description.department Anatomy and Physiology en_US
dc.description.department Centre for Veterinary Wildlife Studies en_US
dc.description.department Paraclinical Sciences en_US
dc.description.department Production Animal Studies en_US
dc.description.sponsorship Agriculture Sector Education Training Authority; Centre for Veterinary Wildlife Research; Department of Paraclinical Sciences, University of Pretoria; Department of Veterinary Tropical Diseases, University of Pretoria; Dnata Wild-over-Wildlife; South African Government Health and Welfare Sector Education and Training Authority; Wiederhold Foundation. en_US
dc.description.uri http://www.wileyonlinelibrary.com/journal/vcp en_US
dc.identifier.citation Mtetwa, TK, Snelling, EP, Donaldson, AC, Buss, PE, Meyer, LCR. Reliability of the Enterprise Point-of-Care (EPOC) blood analyzer's calculated arterial oxygen-hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum). Veterinary Clinical Pathology 2023; 52: 417-421. doi:10.1111/vcp.13236. en_US
dc.identifier.issn 0275-6382 (print)
dc.identifier.issn 1939-165X (online)
dc.identifier.other 10.1111/vcp.13236
dc.identifier.uri http://hdl.handle.net/2263/92992
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.rights © 2023 The Authors. Veterinary Clinical Pathology published by Wiley Periodicals LLC on behalf of the American Society for Veterinary Clinical Pathology. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License. en_US
dc.subject Blood gas analysis en_US
dc.subject Hypoxemia en_US
dc.subject Oxygen saturation en_US
dc.subject Wildlife en_US
dc.subject Enterprise point-of-care (EPOC) en_US
dc.subject White rhinoceros (Ceratotherium simum) en_US
dc.subject SDG-03: Good health and well-being en_US
dc.title Reliability of the enterprise point-of-care (EPOC) blood analyzer's calculated arterial oxygen-hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum) en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record