An investigation into the use of full-body low dose x-rays imaging system in South Africa : radiographer’s perspective

Show simple item record

dc.contributor.author Thambura, Julius Muchui
dc.date.accessioned 2023-09-21T12:29:07Z
dc.date.available 2023-09-21T12:29:07Z
dc.date.issued 2023-09
dc.description.abstract INTRODUCTION : A low dose x-rays alias Lodox© statscan was originally developed in South Africa to detect smuggled diamonds in the mines. Later, hospital trauma units began to use it as a screening tool for gross pathology on trauma patients. This imaging system became popular because of its use of low radiation doses and its ability to perform anterior posterior (head to toe image) image in under 13 seconds. Anecdotal evidence confirms that patients were referred for additional regional images on conventional x-ray systems after Lodox imaging. Thus, patients were subjected to additional ionising radiation, long waiting times as well as additional charges for secondary radiological examinations. OBJECTIVE : This research aimed at investigating the extent to which Lodox was used in trauma units (n=28) in South Africa. METHOD : In this descriptive cross-sectional research. researcher invited one radiographer from each of the 28 hospitals in South Africa that were using Lodox. RESULTS : Out of twenty radiographers who responded, it was found that most hospitals were referring patients for additional conventional x-ray images (Figure 1); for example, for chest x-rays. This was done despite the patient having undergone radiological procedures and examinations by the Lodox imaging system that was similar to those performed by conventional x-ray systems. CONCLUSION : Lodox was used for a successful diagnosis Thus, researcher recommends an imaging protocol for Lodox to be developed for guiding the referral of patients after the Lodox scanning has been performed. en_US
dc.description.department Radiography en_US
dc.description.uri http://www.elsevier.com/locate/afjem en_US
dc.identifier.citation Thambura, M.J., 2023, 'An investigation into the use of full-body low dose x-rays imaging system in South Africa : radiographer's perspective', African Journal of Emergency Medicine, vol. 13, no. 3, pp. 166-170, doi : 10.1016/j.afjem.2023.05.009. en_US
dc.identifier.issn 2211-4203 (online)
dc.identifier.issn 2211-419X(print)
dc.identifier.other 10.1016/j.afjem.2023.05.009
dc.identifier.uri http://hdl.handle.net/2263/92382
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.rights © 2023 The Authors. Published by Elsevier B.V. on behalf of African Federation for Emergency Medicine. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). en_US
dc.subject Lodox en_US
dc.subject Trauma imaging en_US
dc.subject Conventional x-ray system en_US
dc.subject Emergency unit en_US
dc.subject Image quality en_US
dc.subject SDG-03: Good health and well-being en_US
dc.subject Ionising radiation en_US
dc.subject Patient referral en_US
dc.subject Trauma units en_US
dc.subject South Africa (SA) en_US
dc.title An investigation into the use of full-body low dose x-rays imaging system in South Africa : radiographer’s perspective en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record